Review of methods for intraoperative margin detection for breast conserving surgery
Authors:
- Benjamin W. MaloneyBMBenjamin W. Maloney
- Brian W. PogueBPBrian W. Pogue
- Richard J. BarthRBRichard J. Barth
Open Access
- 27 October 2018
- journal article
- review article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (10) , 100901-19
Abstract
Breast conserving surgery (BCS) is an effective treatment for early-stage cancers as long as the margins of the resected tissue are free of disease according to consensus guidelines for patient management. However, 15% to 35% of patients undergo a second surgery since malignant cells are found close to or at the margins of the original resection specimen. This review highlights imaging approaches being investigated to reduce the rate of positive margins, and they are reviewed with the assumption that a new system would need high sensitivity near 95% and specificity near 85%. The problem appears to be twofold. The first is for complete, fast surface scanning for cellular, structural, and/or molecular features of cancer, in a lumpectomy volume, which is variable in size, but can be large, irregular, and amorphous. A second is for full, volumetric imaging of the specimen at high spatial resolution, to better guide internal radiologic decision-making about the spiculations and duct tracks, which may inform that surfaces are involved. These two demands are not easily solved by a single tool. Optical methods that scan large surfaces quickly are needed with cellular/molecular sensitivity to solve the first problem, but volumetric imaging with high spatial resolution for soft tissues is largely outside of the optical realm and requires x-ray, micro-CT, or magnetic resonance imaging if they can be achieved efficiently. In summary, it appears that a combination of systems into hybrid platforms may be the optimal solution for these two very different problems. This concept must be cost-effective, image specimens within minutes and be coupled to decision-making tools that help a surgeon without adding to the procedure. The potential for optical systems to be involved in this problem is emerging and clinical trials are underway in several of these technologies to see if they could reduce positive margin rates in BCS.Keywords
Funding Information
- National Institutes of Health (R01 CA192803)
- NIH or Wellcome Trust (R01 CA192803)
This publication has 101 references indexed in Scilit:
- High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysisBMC Cancer, 2014
- Quantifying Potential Error in Painting Breast Excision SpecimensInternational Journal of Breast Cancer, 2013
- High-frequency ultrasound for intraoperative margin assessments in breast conservation surgery: a feasibility studyBMC Cancer, 2011
- Development of a spatially offset Raman spectroscopy probe for breast tumor surgical margin evaluationJournal of Biomedical Optics, 2011
- Wavelength optimization for rapid chromophore mapping using spatial frequency domain imagingJournal of Biomedical Optics, 2010
- Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence TomographyCancer Research, 2009
- Rapid noninvasive optical imaging of tissue composition in breast tumor marginsThe American Journal of Surgery, 2009
- Combined Screening With Ultrasound and Mammography vs Mammography Alone in Women at Elevated Risk of Breast CancerJAMA, 2008
- Twenty-Year Follow-up of a Randomized Study Comparing Breast-Conserving Surgery with Radical Mastectomy for Early Breast CancerNew England Journal of Medicine, 2002