Compression and Flexural Strength of Bone Cement Mixed with Blood
Open Access
- 30 August 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 24 (2) , 240-244
Abstract
Purpose: To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. Methods: High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1°C for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using micro-computed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. Results: In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Micro-computed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. Conclusion: The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.Keywords
This publication has 31 references indexed in Scilit:
- Cement-Implant Interface Contamination: Possible Reason of Inferior Clinical Outcomes for Rough Surface Cemented StemsThe Open Orthopaedics Journal, 2013
- The Epidemiology of Revision Total Knee Arthroplasty in the United StatesClinical Orthopaedics and Related Research, 2010
- Micro-mechanical modeling of the cement–bone interface: The effect of friction, morphology and material properties on the micromechanical responseJournal of Biomechanics, 2008
- Influence of a Pre-blended Antibiotic (Gentamicin Sulfate Powder) on Various Mechanical, Thermal, and Physical Properties of Three Acrylic Bone CementsJournal of Biomaterials Applications, 2006
- Aseptic looseningGene Therapy, 2004
- Long-term elution of antibiotics from bone-cementThe Journal of Arthroplasty, 1998
- Long-term Results Of Revision Total Hip Arthroplasty With Improved Cementing TechniqueThe Journal of Bone and Joint Surgery. British volume, 1997
- Cemented Total Hip Arthroplasty with Contemporary TechniquesClinical Orthopaedics and Related Research, 1988
- The Influence of Cementing Technique and Blood on the Strength of the Bone-Cement InterfaceEngineering in Medicine, 1988
- The load carrying and fatigue properties of the stem–cement interface with smooth and porous coated femoral componentsJournal of Biomedical Materials Research, 1985