The Determination of the Rapid and Effective Activity of an Air Sanitizer against Aerosolized Bacteria Using a Room-Sized Aerobiology Chamber
Open Access
- 16 October 2024
- journal article
- research article
- Published by MDPI AG in Microorganisms
- Vol. 12 (10) , 2072
Abstract
Air sanitization is an important non-pharmaceutical intervention for mitigating the risk of indoor pathogen spreading. A dipropylene glycol-containing air sanitizer was tested against aerosolized Staphylococcus aureus and Klebsiella pneumoniae. The bacteria, suspended in a soil load, were aerosolized using a six-jet Collison nebulizer with pressurized air. The 25-m3 (~900 ft3) aerobiology chamber was maintained at 22 ± 2 °C and 50 ± 5% relative humidity per the U.S. Environmental Protection Agency’s 2012 Guidelines on air sanitizers. An initial 2-min air sample was collected from the chamber using a slit-to-agar sampler containing 150-mm Petri plates, with Trypticase soy agar (TSA) containing neutralizers to quench the microbicidal activity of the air sanitizer, to determine the initial bacterial challenge in the air. The air sanitizer was sprayed into the chamber from pressurized cans. Additional air samples were collected from the chamber over 10 min to detect surviving bacteria. The TSA plates were then incubated aerobically at 36 ± 1 °C for 90 ± 4 h and scored for bacterial colony-forming units. A 30-s spray of the air sanitizer reduced infectious S. aureus and K. pneumoniae titers by 3.0 log10 (99.9%) in 3.2 ± 0.3 min and 1.2 ± 0.0 min, respectively. Based on these findings, the EPA granted registration of the air sanitizer as the first product of its kind for indoor air sanitization.Keywords
Funding Information
- Reckitt Benckiser
This publication has 25 references indexed in Scilit:
- Airborne pathogenic microorganisms and air cleaning technology development: A reviewJournal of Hazardous Materials, 2022
- Individual- and Household-Level Interventions to Reduce Air Pollution Exposures and Health Risks: a Review of the Recent LiteratureCurrent Environmental Health Reports, 2020
- Environmental Methicillin-resistant Staphylococcus aureus Contamination, Persistent Colonization, and Subsequent Skin and Soft Tissue InfectionJAMA Pediatrics, 2020
- Airborne Staphylococcus aureus in different environments—a reviewEnvironmental Science and Pollution Research, 2019
- Decontamination of indoor air to reduce the risk of airborne infections: Studies on survival and inactivation of airborne pathogens using an aerobiology chamberAmerican Journal of Infection Control, 2016
- Mathematical modeling and simulation of bacterial distribution in an aerobiology chamber using computational fluid dynamicsAmerican Journal of Infection Control, 2016
- Generic aspects of the airborne spread of human pathogens indoors and emerging air decontamination technologiesAmerican Journal of Infection Control, 2016
- Airborne spread of infectious agents in the indoor environmentAmerican Journal of Infection Control, 2016
- Development of methods to study the survival of airborne virusesJournal of Virological Methods, 1987
- AIR STERILIZATION IN AN INFANTS' WARDJAMA, 1951