Indoor/Outdoor Relationships of Airborne Particles under Controlled Pressure Difference across the Building Envelope in Korean Multifamily Apartments
Open Access
- 6 November 2018
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 10 (11) , 4074
Abstract
This study investigates indoor/outdoor relationships of airborne particles under controlled pressure difference across the building envelope in Korean multifamily apartments. On-site field experiments on 14 apartment housing units located in urban areas in Korea are conducted to measure the indoor/outdoor ratios of number concentrations of size-resolved particles (0.3–0.5, 0.5–1.0, 1.0–3.0, 3.0–5.0, 5.0–10.0, >10.0 μm). To set identical pressure difference conditions across the envelope of each housing unit for better comparison of I/O ratio results, and to examine the effect of pressure difference on the I/O relations, indoor–outdoor pressure difference was controlled at 10, 30, and 50 Pa using a blower door depressurization procedure. Simultaneously, the air leakage characteristics of housing units are measured using the typical blower door pressurization-depressurization test method to correlate air leakage data and I/O ratios. As expected, moderately airtight housing units (ACH50 ≤ 4.4) show lower I/O ratios than average leaky housing units (ACH50 > 4.4); still, the averaged I/O ratios of finer sized particles (0.3–0.5, 0.5–1.0, and 1.0–3.0 μm) in the moderately airtight housing units were 0.75, 0.59, and 0.61 at an I-O pressure difference of 50 Pa, and 0.62, 0.51, and 0.49 at 10 Pa. The study indicates that indoor residents in moderately airtight Korean multifamily housing units with relatively small envelope area can still be exposed to high concentrations of outdoor originated fine particles.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017R1C1B2011561, NRF-2018R1D1A1B07050503)
This publication has 28 references indexed in Scilit:
- The effect of particulate matter size on cardiovascular health in Taipei Basin, TaiwanComputer Methods and Programs in Biomedicine, 2016
- Asian dust effect on cause-specific mortality in five cities across South Korea and JapanAtmospheric Environment, 2016
- Contribution of outdoor-originating particles, indoor-emitted particles and indoor secondary organic aerosol (SOA) to residential indoor PM2.5 concentration: A model-based estimationBuilding and Environment, 2015
- Ambient particulate matter (PM10) concentrations in major urban areas of Korea during 1996–2010Atmospheric Pollution Research, 2014
- Seasonal differences of the atmospheric particle size distribution in a metropolitan area in JapanScience of The Total Environment, 2012
- Indoor and outdoor PM2.5 and PM10 concentrations in the air during a dust stormBuilding and Environment, 2010
- Indoor particle dynamicsIndoor Air, 2004
- Air pollution and healthThe Lancet, 2002
- Urban air pollution in megacities of the worldAtmospheric Environment, 1996
- Health effects of particulate air pollution: time for reassessment?Environmental Health Perspectives, 1995