Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients
Open Access
- 13 September 2010
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 49 (7) , 1077-1084
Abstract
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage (15–40%) from the planning CT until the last CBCT. Only five patients presented a significant shrinkage (21–37%) in the GTV-n. Using the daily CBCT imaging, it was found that the mean value of the difference between a setup using the skin tattoo and an online matching using the ITV was 7.3±2.9 mm (3D vector in the direction of ITV). The mean difference between the ITV and bony anatomy matching was 3.0±1.3 mm. Finally, the mean distance between the GTV-t and the GTV-N was 2.9±1.6 mm. Conclusion. One third of all patients with lung cancer undergoing chemo-RT achieved significant tumour shrinkage from planning CT until the end of the radiotherapy. Differences in GTV-t and GTV-n motion was observed and matching using the ITV including both GTV-t and GTV-n is therefore preferable.Keywords
This publication has 23 references indexed in Scilit:
- Patient setup error and day-to-day esophageal motion error analyzed by cone-beam computed tomography in radiation therapyActa Oncologica, 2010
- Motion Analysis of 100 Mediastinal Lymph Nodes: Potential Pitfalls in Treatment Planning and Adaptive StrategiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Tumor Localization Using Cone-Beam CT Reduces Setup Margins in Conventionally Fractionated Radiotherapy for Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Dose–volume thresholds and smoking status for the risk of treatment-related pneumonitis in inoperable non-small cell lung cancer treated with definitive radiotherapyRadiotherapy and Oncology, 2009
- Quantification of Tumor Volume Changes During Radiotherapy for Non–Small-Cell Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Cone-Beam Computed Tomographic Image Guidance for Lung Cancer Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Cone beam CT evaluation of patient set-up accuracy as a QA toolActa Oncologica, 2009
- Interfractional changes in tumour volume and position during entire radiotherapy courses for lung cancer with respiratory gating and image guidanceActa Oncologica, 2008
- The role of radiotherapy in lung cancer: Where is the evidence?Radiotherapy and Oncology, 2007
- Megavoltage Imaging, Megavoltage Cone Beam CT and Dose-Guided Radiation Therapy2007