Intraoperative near-infrared lymphography with indocyanine green may aid lymph node dissection during robot-assisted resection of gastroesophageal junction cancer
Authors:
- 21 October 2022
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (3) , 1985-1993
Abstract
Background Adequate lymphadenectomy during gastroesophageal junction (GEJ) cancer resection is essential, because lymph node (LN) metastasis correlates with increased recurrence risk. Fluorescence lymphography with indocyanine green (ICG) has been used for LN mapping in several surgical specialties; however, reports on GEJ cancer are lacking. Therefore, we investigated whether intraoperative ICG lymphography could facilitate LN harvest during robot-assisted resection of GEJ cancer. Methods Patients scheduled for robot-assisted resection of GEJ cancer were included, and outcomes were compared with historical controls. After intraoperative endoscopic submucosal ICG injection, standard D1 + LN dissection was performed under white light. Then, near-infrared (NIR) fluorescence imaging was activated, and each LN dissection area was re-examined. Any tissue within the D1 + field exhibiting distinctly increased ICG fluorescence compared with background tissue was dissected and sent for pathology review. Results We included 70 patients between June 2020 and October 2021. Three cases were aborted due to disseminated disease, and two were converted to open resection and excluded from the analysis. Additional tissue was dissected after NIR review in 34 of 65 (52%) patients. We dissected 43 fluorescent tissue samples, and after pathology review, 30 were confirmed LNs; none were metastatic. The median number of LNs harvested per patient (34, interquartile range [IQR] = 26–44) was not significantly different from that harvested from historical controls (32, IQR = 24–45; p = 0.92), nor were there any differences between these two groups in the duration of surgery, intraoperative blood loss, or comprehensive complication scores (p = 0.12, p = 0.46, and p = 0.41, respectively). Conclusions Intraoperative NIR lymphography with ICG may aid LN detection during robot-assisted resection of GEJ cancer without increasing surgical risk. Although NIR lymphography may facilitate LN dissection, none of the LN removed after the NIR review was metastatic. Hence, it remains uncertain whether NIR lymphography will improve oncological outcomes.Keywords
Funding Information
- Medtronic (OPI-projekt)
- Grosserer LF Foghts Fond (21807)
- Fabrikant Einar Willumsens Mindelegat (500028)
- Aase og Ejnar Danielsens Fond (no number)
This publication has 32 references indexed in Scilit:
- Status and prognosis of lymph node metastasis in patients with cardia cancer – A systematic reviewSurgical Oncology, 2014
- Feasibility and Optimal Dosage of Indocyanine Green Fluorescence for Sentinel Lymph Node Detection Using Robotic Single-Site Instrumentation: Preclinical StudyJournal of Minimally Invasive Gynecology, 2013
- Adverse events of upper GI endoscopyGastrointestinal Endoscopy, 2012
- The Impact of Heavy Smoking on Anastomotic Leakage and Stricture After Low Anterior Resection in Rectal Cancer PatientsWorld Journal of Surgery, 2011
- Impact of the method of reconstruction after oncologic oesophagectomy on quality of life — a prospective, randomised studyEuropean Journal of Cardio-Thoracic Surgery, 2011
- Gastric cancerThe Lancet, 2009
- The Clavien-Dindo Classification of Surgical ComplicationsAnnals of Surgery, 2009
- Mapping sentinel nodes in patients with early-stage gastric carcinomaBritish Journal of Surgery, 2003
- Factors Associated with Tolerance to, and Discomfort with, Unsedated Diagnostic GastroscopyScandinavian Journal of Gastroenterology, 2001
- SIMULTANEOUS INDOCYANINE GREEN AND FLUORESCEIN ANGIOGRAPHYRetina, 1995