Acute Respiratory Syndrome After Inhalation of Waterproofing Sprays: A Posteriori Exposure-Response Assessment in 102 Cases
Authors:
- David VernezDVDavid Vernez
- Raffaella BruzziRBRaffaella Bruzzi
- Hugo KupferschmidtHKHugo Kupferschmidt
- Alice De-BatzADAlice De-Batz
- Pierre DrozPDPierre Droz
- Romain LazorRLRomain Lazor
- 1 June 2006
- journal article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 3 (5) , 250-261
Abstract
Waterproofing agents are widely used to protect leather and textiles in both domestic and occupational activities. An outbreak of acute respiratory syndrome following exposure to waterproofing sprays occurred during the winter 2002-2003 in Switzerland. About 180 cases were reported by the Swiss Toxicological Information Centre between October 2002 and March 2003, whereas fewer than 10 cases per year had been recorded previously. The reported cases involved three brands of sprays containing a common waterproofing mixture, that had undergone a formulation change in the months preceding the outbreak. A retrospective analysis was undertaken in collaboration with the Swiss Toxicological Information Centre and the Swiss Registries for Interstitial and Orphan Lung Diseases to clarify the circumstances and possible causes of the observed health effects. Individual exposure data were generated with questionnaires and experimental emission measurements. The collected data was used to conduct numeric simulation for 102 cases of exposure. A classical two-zone model was used to assess the aerosol dispersion in the near- and far-field during spraying. The resulting assessed dose and exposure levels obtained were spread on large scales, of several orders of magnitude. No dose-response relationship was found between exposure indicators and health effects indicators (perceived severity and clinical indicators). Weak relationships were found between unspecific inflammatory response indicators (leukocytes, C-reactive protein) and the maximal exposure concentration. The results obtained disclose a high interindividual response variability and suggest that some indirect mechanism(s) predominates in the respiratory disease occurrence. Furthermore, no threshold could be found to define a safe level of exposure. These findings suggest that the improvement of environmental exposure conditions during spraying alone does not constitute a sufficient measure to prevent future outbreaks of waterproofing spray toxicity. More efficient preventive measures are needed prior to the marketing and distribution of new waterproofing agents.Keywords
This publication has 14 references indexed in Scilit:
- Characterizing Emission and Breathing-Zone Concentrations Following Exposure Cases to Fluororesin-Based Waterproofing Spray MistsJournal of Occupational and Environmental Hygiene, 2004
- Acute pulmonary toxicity following occupational exposure to a floor stain protector in the building industry in SwitzerlandInternational Archives of Occupational and Environmental Health, 2004
- Methods for Estimating the Transfer Efficiency of a Compressed Air Spray GunApplied Occupational and Environmental Hygiene, 2002
- Fluorinated Coatings and Films: Motivation and Significance2001
- Modeling Breathing-Zone Concentrations of Airborne Contaminants Generated During Compressed Air Spray PaintingAnnals of Occupational Hygiene, 1999
- Acute Lung Injury Induced by a Commercial Leather ConditionerToxicology and Applied Pharmacology, 1997
- Pulmonary Toxicity Following Exposure to an Aerosolized Leather ProtectorJournal of Toxicology: Clinical Toxicology, 1996
- Pulmonary Collapse and Pneumonia Due to Inhalation of a Waterproofing Aerosol in Female CD-I MiceJournal of Toxicology: Clinical Toxicology, 1995
- Vergiftungen durch Leder-Imprägniersprays: Eine retrospektive Analyse über 224 VergiftungsfälleDMW - Deutsche Medizinische Wochenschrift, 1983
- Inhalationsintoxikation durch LederimprägnationsmittelDMW - Deutsche Medizinische Wochenschrift, 1982