Validation of two automated ASPECTS software on non-contrast computed tomography scans of patients with acute ischemic stroke
Authors:
Open Access
- 6 April 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 14
Abstract
Purpose: The Alberta Stroke Program Early Computed Tomography Score (ASPECTS) was designed for semi-quantitative assessment of early ischemic changes on non-contrast computed tomography (NCCT) for acute ischemic stroke (AIS). We evaluated two automated ASPECTS software in comparison with reference standard.Methods: NCCT of 276 AIS patients were retrospectively reviewed (March 2018–June 2020). A three-radiologist consensus for ASPECTS was used as reference standard. Imaging data from both baseline and follow-up were evaluated for reference standard. Automated ASPECTS were calculated from baseline NCCT with 1-mm and 5-mm slice thickness, respectively. Agreement between automated ASPECTS and reference standard was assessed using intra-class correlation coefficient (ICC). Correlation of automated ASPECTS with baseline stroke severity (NIHSS) and follow-up ASPECTS were evaluated using Spearman correlation analysis.Results: In score-based analysis, automated ASPECTS calculated from 5-mm slice thickness images agreed well with reference standard (software A: ICC = 0.77; software B: ICC = 0.65). Bland–Altman analysis revealed that the mean differences between automated ASPECTS and reference standard were ≤ 0.6. In region-based analysis, automated ASPECTS derived from 5-mm slice thickness images by software A showed higher sensitivity (0.60 vs. 0.54), lower specificity (0.91 vs. 0.94), and higher AUC (0.76 vs. 0.74) than those using 1-mm slice thickness images (p < 0.05). Automated ASPECTS derived from 5-mm slice thickness images by software B showed higher sensitivity (0.56 vs. 0.51), higher specificity (0.87 vs. 0.81), higher accuracy (0.80 vs. 0.73), and higher AUC (0.71 vs. 0.66) than those using 1-mm slice thickness images (p < 0.05). Automated ASPECTS were significantly associated with baseline NIHSS and follow-up ASPECTS.Conclusion: Automated ASPECTS showed good reliability and 5 mm was the optimal slice thickness.Keywords
This publication has 29 references indexed in Scilit:
- ASPECTS CT in Acute IschemiaTopics in Magnetic Resonance Imaging, 2017
- Admission CT perfusion may overestimate initial infarct core: the ghost infarct core conceptJournal of NeuroInterventional Surgery, 2016
- Early CT changes in patients admitted for thrombectomyNeurology, 2016
- Exclusion of Isolated Cortical Swelling Can Increase Efficacy of Baseline Alberta Stroke Program Early CT Score in the Prediction of Prognosis in Acute Ischemic Stroke Patients Treated with ThrombolysisJournal of Stroke and Cerebrovascular Diseases, 2015
- Automated brain computed tomographic densitometry of early ischemic changes in acute strokeJournal of Medical Imaging, 2015
- Computer-Aided Diagnosis of Hyperacute Stroke with Thrombolysis Decision Support Using a Contralateral Comparative Method of CT Image AnalysisJournal of Digital Imaging, 2014
- Prediction of Poststroke Hemorrhagic Transformation Using Computed Tomography PerfusionStroke, 2013
- Thin-Slice Reconstructions of Nonenhanced CT Images Allow for Detection of Thrombus in Acute StrokeStroke, 2012
- Perfusion-CT Assessment of Infarct Core and PenumbraStroke, 2006
- Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapyThe Lancet, 2000