Robust pCASL perfusion imaging using a 3D Cartesian acquisition with spiral profile reordering (CASPR)
- 23 June 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (5) , 1713-1724
Abstract
Purpose: To improve the robustness of arterial spin‐labeled measured perfusion using a novel Cartesian acquisition with spiral profile reordering (CASPR) 3D turbo spin echo (TSE) in the brain and kidneys.Methods: The CASPR view ordering followed a pseudo‐spiral trajectory on a Cartesian grid, by sampling the center of k‐space at the beginning of each echo train of a segmented 3D TSE acquisition. With institutional review board approval and written informed consent, 14 normal subjects (9 brain and 5 kidneys) were scanned with pCASL perfusion imaging using 3D CASPR and compared against 3D linear TSE (brain and kidneys), the established 2D EPI and 3D gradient and spin echo perfusion (brain), and 2D single‐shot turbo spin‐echo perfusion (kidneys). The SNR and the quantitative perfusion values were compared among different acquisitions.Results: 3D CASPR TSE achieved robust perfusion across all slices compared to 3D linear TSE in the brain and kidneys. Compared to 2D EPI, 3D CASPR TSE showed higher SNR across the brain (P < 0.01), and exhibited good agreement (36.4 ± 4.7 and 36.9 ± 5.3 mL/100 g/min with 2D EPI and 3D CASPR, respectively), and with 3D gradient and spin echo (27.9 ± 7.2 mL/100 g/min). Compared to a single slice 2D single‐shot turbo spin‐echo acquisition, 3D CASPR TSE achieved robust perfusion across the entire kidneys in similar scan time with comparable quantified perfusion values (154.1 ± 74.6 and 151.7 ± 70.6 mL/100 g/min with 2D single‐shot turbo spin‐echo and 3D CASPR, respectively).Conclusion: The CASPR view ordering with 3D TSE achieves robust arterial spin‐labeled perfusion in the brain and kidneys because of the sampling of the center of k‐space at the beginning of each echo train.Keywords
Funding Information
- National Cancer Institute (P50CA196516, R01CA154475, U01CA207091)
This publication has 34 references indexed in Scilit:
- Optimization of background suppression for arterial spin labeling perfusion imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 2011
- Arterial Spin-Labeled MR Perfusion Imaging: Clinical ApplicationsMagnetic Resonance Imaging Clinics of North America, 2009
- Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 2009
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- Perfusion Imaging of Brain Tumors Using Arterial Spin-Labeling: Correlation with Histopathologic Vascular DensityAmerican Journal of Neuroradiology, 2008
- Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniquesBritish Journal of Radiology, 2006
- Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurementsMagnetic Resonance in Medicine, 2005
- Spiral imaging: A critical appraisalJournal of Magnetic Resonance Imaging, 2005
- Susceptibility Contrast and Arterial Spin Labeled Perfusion MRI in Cerebrovascular DiseaseJournal of Neuroimaging, 2003
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991