Impact of a hospital-wide huddle on device utilisation and infection rates: a community hospital’s journey to zero
- 21 July 2020
- journal article
- research article
- Published by SAGE Publications in Journal of Infection Prevention
- Vol. 21 (6) , 228-233
Abstract
Background: Device utilisation ratios (DUR) correlate with device-associated complications and rates of infection. We implemented a hospital-wide Daily Interdisciplinary Safety Huddle (DISH) with infection control and device components. The aim of this study was to evaluate the impact of DISH on DURs and rates of infection for indwelling urinary catheters (IUC) and central venous catheters (CVC). Methods: A quasi-experimental study assessing DURs and rates of infection before and after implementation of DISH. At DISH, usage of IUC and CVC is reported by managers and the infection preventionist reviews indications and plans for removal. Data before and after implementation were compared. Paired T-test was used to assess for differences between both groups. Results: DISH was successfully implemented at a community hospital. The average DUR for IUC in intensive care unit (ICU) and non-ICU settings was reduced from 0.56 to 0.35 and 0.27 to 0.12, respectively. CVC DUR decreased from 0.29 to 0.26 in the ICU and 0.14 to 0.12 in non-ICU settings. Catheter-associated urinary tract infections (CAUTIs) decreased by 87% and central line-associated bloodstream infections (CLABSIs) by 96%. Conclusion: DISH was associated with hospital-wide reductions in DUR and device-associated healthcare-associated infections. Reduction of CLABSIs and CAUTIs had estimated cost savings of $688,050. The impact was more profound in non-ICU settings. To our knowledge, an infection prevention hospital-wide safety huddle has not been reported in the literature. DISH increased device removal, accountability and promoted a culture of safety.Keywords
This publication has 14 references indexed in Scilit:
- Safety huddles to proactively identify and address electronic health record safetyJournal of the American Medical Informatics Association, 2016
- Fostering a Culture of Safety: The OR HuddleAORN Journal, 2015
- Beyond Infection: Device Utilization Ratio as a Performance Measure for Urinary Catheter HarmInfection Control & Hospital Epidemiology, 2015
- The Ann Arbor Criteria for Appropriate Urinary Catheter Use in Hospitalized Medical Patients: Results Obtained by Using the RAND/UCLA Appropriateness MethodAnnals of Internal Medicine, 2015
- Strategies to Prevent Catheter-Associated Urinary Tract Infections in Acute Care Hospitals: 2014 UpdateInfection Control & Hospital Epidemiology, 2014
- Strategies to Prevent Central Line-Associated Bloodstream Infections in Acute Care Hospitals: 2014 UpdateInfection Control & Hospital Epidemiology, 2014
- Guidelines for the Prevention of Intravascular Catheter-related InfectionsClinical Infectious Diseases, 2011
- Summary of Recommendations: Guidelines for the Prevention of Intravascular Catheter-related InfectionsClinical Infectious Diseases, 2011
- Guideline for Prevention of Catheter-Associated Urinary Tract Infections 2009Infection Control & Hospital Epidemiology, 2010
- Diagnosis, Prevention, and Treatment of Catheter-Associated Urinary Tract Infection in Adults: 2009 International Clinical Practice Guidelines from the Infectious Diseases Society of AmericaClinical Infectious Diseases, 2010