PERFORMANCE OF THICK-SORBENT DIFFUSIVE SAMPLERS
Authors:
- 1 August 1988
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 32 (3) , 333-343
Abstract
Errors of estimates of concentration in the diffusive sampling of analytes weakly bound to finite-thickness sorbents are investigated both theoretically and experimentally. Experimental data are presented for sampling concentration pulses of trichloroethylene. using a column of activated charcoal as sorbent. Analysis indicates that analyte loss results in errors in estimates of 8-h time-weighted averages (TWA) between —17 and 51%, the extreme values corresponding to short pulses occurring at the beginning or end of the sampling period, respectively. Experiments were also conducted on pulse sampling using a sampler which employs a liquid (in this case, water) column as sorbent. Both acetone (weakly bound) and methanol (more strongly bound) were studied so as to cover a range of physical phenomena. Limits of several mathematical approximations are discussed within the framework of these experiments.Keywords
This publication has 6 references indexed in Scilit:
- Diffusive Samplers Using Longitudinal Sorbent StripsAIHA Journal, 1986
- A Thermodynamic Treatment of Passive MonitorsAIHA Journal, 1985
- Critical Parameters for the Adsorption of Gaseous Pollutants on Passive Samplers Made of Low Specific Area AdsorbentsAnalytical Letters, 1985
- Stain Length Passive Dosimeter for Monitoring of Carbon MonoxideAIHA Journal, 1983
- An experimental comparison of three diffusion samplers exposed to concentration profiles of organic vaporsAIHA Journal, 1982
- Transient response of diffusion dosimetersAIHA Journal, 1980