Non-unit Traveling Wave Protection of HVDC Grids Using Levenberg–Marquart Optimal Approximation
- 7 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (5) , 2260-2271
Abstract
The fast and selective protection using fast dc circuit breaker to break the fault current and isolate faulty lines satisfies the requirement of fault clearance in HVDC grids. However, traditional derivative-based traveling wave protection suffers from low-sensitivity problem when high-impedance faults occur. Based on the analysis of the fault initial traveling wave, it is concluded that the distortion degree of the fault initial traveling wave is related to the location of the fault, and the amplitude of the fault initial traveling wave is related to the fault impedance. Then a Levenberg-Marquart (LM) optimal approximation method is proposed to extract the fault distance information from zero-sequence fault current initial traveling wave. The optimal approximation parameters respectively reflecting the fault distance and fault impedance can be obtained. A non-unit traveling wave protection scheme is proposed based on the parameters. A ±400kV modular multilevel converter (MMC) HVDC grid test system is built in PSCAD/EMTDC to verify the proposed method. The simulation results show that the parameters can directly correspond to the fault distance and fault impedance, and the proposed method can fast and reliably identify dc line faults. Finally, the sensitivity of the proposed method is studied by comparing with three different methods.Keywords
Funding Information
- National Key Research and Development Program of China Stem Cell and Translational Research (2016YFB0900603)
- State Grid Corporation of China (52094017000W)
- National Natural Science Foundation of China (U1766209)
This publication has 23 references indexed in Scilit:
- Transient measured impedance‐based protection scheme for DC line faults in ultra high‐voltage direct‐current systemIET Generation, Transmission & Distribution, 2016
- DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change RateIEEE Transactions on Power Delivery, 2016
- An Alternative Method to Build DC Switchyard With Hybrid DC Breaker for DC GridIEEE Transactions on Power Delivery, 2016
- A Non-unit Protection Scheme for DC Microgrid Based on Local MeasurementsIEEE Transactions on Power Delivery, 2016
- An Improved Traveling-Wave Protection Scheme for LCC-HVDC Transmission LinesIEEE Transactions on Power Delivery, 2016
- Assembly HVDC Breaker for HVDC Grids With Modular Multilevel ConvertersIEEE Transactions on Power Electronics, 2016
- Nonunit Protection of HVDC Grids With Inductive DC Cable TerminationIEEE Transactions on Power Delivery, 2015
- Fault Detection and Interruption in an Earthed HVDC Grid Using ROCOV and Hybrid DC BreakersIEEE Transactions on Power Delivery, 2014
- On the Bipolar MMC-HVDC Topology Suitable for Bulk Power Overhead Line Transmission: Configuration, Control, and DC Fault AnalysisIEEE Transactions on Power Delivery, 2014
- Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and FunctionalitiesIEEE Transactions on Power Electronics, 2014