Comparison of five classification systems for interpreting electronic fetal monitoring in predicting neonatal status at birth
- 6 November 2012
- journal article
- research article
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 26 (5) , 487-490
Abstract
Objective: To compare the accuracy of five different classification systems for interpreting electronic fetal monitoring (EFM) when predicting neonatal status at birth, as determined by the umbilical cord arterial pH. Methods: Ninety-seven cardiotocography traces were retrospectively interpreted according to five classification systems for EFM: Dublin Fetal Heart Rate Monitoring Trial (DFHRMT), Royal College of Obstetricians and Gynecologists (RCOG), Society of Obstetricians and Gynaecologists of Canada (SOGC), National Institute of Child Health and Human Development (NICHD) and Parer & Ikeda’s. For each classification system, sensitivity, specificity, positive and negative predictive values were calculated. The capacity of the classifications to predict neonatal pH was also evaluated by receiver-operating characteristic (ROC) curves. Agreement between the five systems was estimated using weighted kappa statistic. Results: Considering pH ≤7.15 as the cutoff for low pH, the sensitivity and specificity values were 100 and 18% (DFHRMT); 100 and 15% (RCOG); 88 and 37% (SOGC); 67 and 92% (NICHD); 55 and 67% (Parer & Ikeda). The ROC curves showed that all classifications analyzed had a low discriminative capacity when predicting umbilical artery pH ≤7.15. An excellent agreement was observed between DFHRMT and RCOG (weighted κ value: 0.860). Conclusions: Parer & Ikeda and NICHD classifications had the highest specificity in detecting umbilical cord arterial pH ≤7.15. The high specificity of the NICHD classification is hindered by a high percentage of “intermediate” traces (80%). Parer & Ikeda classification is the one that best classify as pathological only the traces of fetuses that are truly at risk of acidemia, thus avoiding unnecessary intervention. It also showed the best trade-off between sensitivity and specificity and the lowest rate of traces considered “intermediate.”Keywords
This publication has 10 references indexed in Scilit:
- The 5-tier system of assessing fetal heart rate tracings is superior to the 3-tier system in identifying fetal acidemiaAmerican Journal of Obstetrics and Gynecology, 2012
- Assessment of the concordance among 2-tier, 3-tier, and 5-tier fetal heart rate classification systemsAmerican Journal of Obstetrics and Gynecology, 2011
- Comments on American College of Obstetricians and Gynecologists Practice Bulletin No. 106American Journal of Obstetrics and Gynecology, 2010
- ACOG Practice Bulletin No. 106: Intrapartum Fetal Heart Rate Monitoring: Nomenclature, Interpretation, and General Management PrinciplesObstetrics & Gynecology, 2009
- The 2008 National Institute of Child Health and Human Development Workshop Report on Electronic Fetal MonitoringObstetrics & Gynecology, 2008
- RETIRED: Fetal Health Surveillance: Antepartum and Intrapartum Consensus GuidelineJournal of Obstetrics and Gynaecology Canada, 2007
- A framework for standardized management of intrapartum fetal heart rate patternsAmerican Journal of Obstetrics and Gynecology, 2007
- ACOG Committee Opinion No. 348: Umbilical Cord Blood Gas and Acid-Base AnalysisObstetrics & Gynecology, 2006
- 5 Intrapartum fetal monitoringBailliere's Clinical Obstetrics and Gynaecology, 1987
- The Dublin randomized controlled trial of intrapartum fetal heart rate monitoringAmerican Journal of Obstetrics and Gynecology, 1985