Robotic Diagnostic Cerebral Angiography: A Multicenter Experience of 113 Patients
- 19 July 2023
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (7) , 726-730
Abstract
Background Neurointerventional robotic systems have potential to reduce occupational radiation, improve procedural precision, and allow for future remote teleoperation. A limited number of single institution case reports and series have been published outlining the safety and feasibility of robot-assisted diagnostic cerebral angiography. Methods This is a multicenter, retrospective case series of patients undergoing diagnostic cerebral angiography at three separate institutions – University of California, Davis (UCD); University of California, Los Angeles (UCLA); and University of California, San Francisco (UCSF). The equipment used was the CorPath GRX Robotic System (Corindus, Waltham, MA). Results A total of 113 cases were analyzed who underwent robot-assisted diagnostic cerebral angiography from September 28, 2020 to October 27, 2022. There were no significant complications related to use of the robotic system including stroke, arterial dissection, bleeding, or pseudoaneurysm formation at the access site. Using the robotic system, 88 of 113 (77.9%) cases were completed successfully without unplanned manual conversion. The principal causes for unplanned manual conversion included challenging anatomy, technical difficulty with the bedside robotic cassette, and hubbing out of the robotic system due to limited working length. For robotic operation, average fluoroscopy time was 13.2 min (interquartile range (IQR), 9.3 to 16.8 min) and average cumulative air kerma was 975.8 mGY (IQR, 350.8 to 1073.5 mGy). Conclusions Robotic cerebral angiography with the CorPath GRX Robotic System is safe and easily learned by novice users without much prior manual experience. However, there are technical limitations such as a short working length and an inability to support 0.035” wires which may limit its widespread adoption in clinical practice.Keywords
This publication has 12 references indexed in Scilit:
- Reported Events Associated With Spine Robots: An Analysis of the Food and Drug Administration’s Manufacturer and User Facility Device Experience DatabaseGlobal Spine Journal, 2022
- Robotics in neurointerventional surgery: a systematic review of the literatureJournal of NeuroInterventional Surgery, 2021
- Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference LevelsNeurointervention, 2021
- Transradial cerebral angiography becomes more efficient than transfemoral angiography: lessons from 500 consecutive angiogramsJournal of NeuroInterventional Surgery, 2021
- A Review of Robotic Interventional NeuroradiologyAmerican Journal of Neuroradiology, 2021
- Low-Dose Fluoroscopy Protocol for Diagnostic Cerebral AngiographyNeurointervention, 2020
- Time to Treatment With Endovascular Thrombectomy and Outcomes From Ischemic Stroke: A Meta-analysisJAMA, 2016
- Every 15-Min Delay in Recanalization by Intra-Arterial Therapy in Acute Ischemic Stroke Increases Risk of Poor OutcomeInternational Journal of Stroke, 2015
- Safety and Feasibility of Robotic Percutaneous Coronary InterventionJACC, 2013
- Neurologic Complications of Cerebral Angiography: Prospective Analysis of 2,899 Procedures and Review of the LiteratureRadiology, 2003