Overdenture retaining bar stress distribution: A finite-element analysis
- 2 February 2015
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 73 (4) , 274-279
Abstract
Objective. Evaluate the stress distribution on the peri-implant bone tissue and prosthetic components of bar-clip retaining systems for overdentures presenting different implant inclinations, vertical misfit and framework material. Materials and methods. Three-dimensional models of a jaw and an overdenture retained by two implants and a bar-clip attachment were modeled using specific software (SolidWorks 2010). The studied variables were: latero-lateral inclination of one implant (–10°, –5°, 0°, +5°, +10°); vertical misfit on the other implant (50, 100, 200 µm); and framework material (Au type IV, Ag-Pd, Ti cp, Co-Cr). Solid models were imported into mechanical simulation software (ANSYS Workbench 11). All nodes on the bone’s external surface were constrained and a displacement was applied to simulate the settling of the framework on the ill-fitted component. Von Mises stress for the prosthetic components and maximum principal stress to the bone tissue were evaluated. Results. The +10° inclination presented the worst biomechanical behavior, promoting the highest stress values on the bar framework and peri-implant bone tissue. The –5° group presented the lowest stress values on the prosthetic components and the lowest stress value on peri-implant bone tissue was observed in –10°. Increased vertical misfit caused an increase on the stress values in all evaluated structures. Stiffer framework materials caused a considerable stress increase in the framework itself, prosthetic screw of the fitted component and peri-implant bone tissue. Conclusions. Inclination of one implant associated with vertical misfit caused a relevant effect on the stress distribution in bar-clip retained overdentures. Different framework materials promoted increased levels of stress in all the evaluated structures.Keywords
This publication has 18 references indexed in Scilit:
- The Influence of Clip Material and Cross Sections of the Bar Framework Associated with Vertical Misfit on Stress Distribution in Implant-Retained OverdenturesThe International Journal of Prosthodontics, 2014
- Effect of bar cross-section geometry on stress distribution in overdenture-retaining system simulating horizontal misfit and bone lossJournal of Biomechanics, 2013
- Complication rates and patient satisfaction with removable denturesThe Journal of Advanced Prosthodontics, 2012
- Effects of Horizontal Misfit and Bar Framework Material on the Stress Distribution of an Overdenture-Retaining Bar System: A 3D Finite Element AnalysisJournal of Prosthodontics, 2011
- Patients' Expectations Before and Evaluation After Dental Implant TherapyClinical Implant Dentistry and Related Research, 2011
- The Use of Mandibular Implant-retained Overdentures Improve Patient Satisfaction and Quality of LifeJournal of Evidence-Based Dental Practice, 2010
- General health of elderly institutionalised and community-dwelling BraziliansGerodontology, 2007
- Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesisDental Materials, 2006
- Improving the oral health of older people: the approach of the WHO Global Oral Health ProgrammeCommunity Dentistry and Oral Epidemiology, 2005
- Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year reportThe Journal of Prosthetic Dentistry, 1991