Differences in corneal astigmatism between partial coherence interferometry biometry and automated keratometry and relation to topographic pattern
Authors:
- Su Yeon KangSKSu Yeon Kang
- Hyo-Myung KimHKHyo-Myung Kim
- Jong-Suk SongJSJong-Suk Song
- 1 September 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (9) , 1694-1698
Abstract
To compare the corneal astigmatism values obtained with a partial coherence interferometry (PCI) biometer and an automated keratometer and to evaluate the association between these differences and corneal topographic patterns. Department of Ophthalmology, Guro Hospital, Korea University College of Medicine, Seoul, Korea. Comparative case series. Corneal astigmatism was measured by PCI biometry (IOLMaster) and automated keratometry (RK-F1 autorefractor). Eyes were divided into 3 groups based on the difference in absolute astigmatism values between PCI biometry and automated keratometry (ie, PCI biometry - automated keratometry) as follows: Group 1, more than 0.25 diopter (D); Group 2, within ±0.25 D; Group 3, less than -0.25 D. The topographic maps were grouped into patterns of round, oval, symmetric bow tie, asymmetric bow tie, and irregular. Distributions of topographic patterns according to group and astigmatism values by topographic patterns were evaluated. The study enrolled 312 eyes. The most common pattern was the asymmetric bow tie (34.6%) followed by symmetric bow tie (20.5%), round (18.9%), irregular (16.3%), and oval (9.6%). The asymmetric bow-tie pattern was the most common in Group 1 and Group 2 (36.1% and 50.0%, respectively); however, in Group 3, the symmetric bow-tie pattern was the most common (32.8%). The distribution of topographic patterns by groups was statistically significantly different (P=.015, Pearson chi-square test). The difference in corneal astigmatism between the PCI biometer and automated keratometer may depend on the corneal topography pattern.Keywords
This publication has 18 references indexed in Scilit:
- Early experience with the AcrySof toric IOL for the correction of astigmatism in cataract surgeryCanadian Journal of Ophthalmology, 2009
- Refractive Lens Exchange with Foldable Toric Intraocular LensAmerican Journal of Ophthalmology, 2009
- Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgeryJournal of Cataract & Refractive Surgery, 2009
- Astigmatism management in cataract surgery with the AcrySof toric intraocular lensJournal of Cataract & Refractive Surgery, 2008
- Foldable toric intraocular lens for astigmatism correction in cataract patientsJournal of Cataract & Refractive Surgery, 2008
- Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation controlJournal of Cataract & Refractive Surgery, 2007
- Status of toric intraocular lensesCurrent Opinion in Ophthalmology, 2007
- Limbal relaxing incisions versus on-axis incisions to reduce corneal astigmatism at the time of cataract surgeryJournal of Cataract & Refractive Surgery, 2005
- Cataract patients in a defined Swedish population 1986–1990Acta Ophthalmologica, 1994
- Incidence of Astigmatism in a Cataract PracticeJournal of Refractive Surgery, 1988