Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience
Authors:
Open Access
- 25 January 2021
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (3) , 580-587
Abstract
Introduction: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA‐Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems.Methods: One hundred and ten consecutive patients who underwent first‐time cryoballoon ablation (POLARx: n = 57; AFA‐Pro: n = 53) were included in this prospective cohort study.Results: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA‐Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p < .001) and balloon in body time (51 vs. 35 min, p < .001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature −30°C (27 vs. 31 s, p < .001) and −40°C (32 vs. 54 s, p < .001), lower balloon nadir temperature (−55°C vs. −47°C, p < .001), and longer thawing time till 0°C (16 vs. 9 s, p < .001). There were no differences in time‐to‐isolation (TTI; POLARx: 45 s vs. AFA‐Pro 43 s, p = .441), however, POLARx was associated with a lower balloon temperature at TTI (−46°C vs. −37°C, p < .001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA‐Pro: 3.7%).Conclusion: The novel cryoballoon is comparable to AFA‐Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower balloon temperatures but TTI was similar to AFA‐Pro.Keywords
This publication has 21 references indexed in Scilit:
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationThe New England journal of medicine, 2016
- Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillationHeart Rhythm, 2016
- Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial FibrillationCirculation, 2015
- Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillationHeart Rhythm, 2013
- Validation of a novel spiral mapping catheter for real-time recordings from the pulmonary veins during cryoballoon ablation of atrial fibrillationHeart Rhythm, 2013
- Single Transseptal Big Cryoballoon Pulmonary Vein Isolation using an Inner Lumen Mapping CatheterPacing and Clinical Electrophysiology, 2012
- Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility studyEP Europace, 2012
- Cryoballoon temperature predicts acute pulmonary vein isolationHeart Rhythm, 2011
- Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural successJournal of Interventional Cardiac Electrophysiology, 2011
- Circumferential Pulmonary Vein Isolation With the Cryoballoon TechniqueJACC, 2008