The utility of cemented femoral stems in modern THA: a 10-year comparative analysis of the Charnley and Exeter stems
Open Access
- 27 May 2023
- journal article
- research article
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 193 (1) , 251-255
Abstract
Background: Total hip replacement (THR) is one of the most common surgical procedures performed worldwide. The controversy surrounding the relative merits of a cemented composite beam or cemented taper-slip stem in total hip replacement continues. Our aims primarily were to assess the 10-year outcomes of cemented stems using Charnley and Exeter prostheses with regional registry data and secondarily to assess the main predictors of revision. Methods: We prospectively collected registry data for procedures performed between January 2005 and June 2008. Only cemented Charnley and Exeter stems were included. Patients were prospectively reviewed at 6 months, 2, 5 and 10 years. The primary outcome measure was a 10-year all-cause revision. Secondary outcomes included ‘re-revision’, ‘mortality’ and functional ‘Western Ontario and McMaster Universities Osteoarthritis Index’ (WOMAC) scores. Results: We recorded a total of 1351 cases in the cohort, 395 Exeter and 956 Charnley stems. The overall all-cause revision rate at 10 years was 1.6%. The revision rate for Charnley stem was 1.4% and 2.3% revision rate for all Exeter stems with no significant difference noted between the two cohorts (p = 0.24). The overall time to revision was 38.3 months. WOMAC scores at 10 years were found to be insignificantly higher for Charnley stems (mean 23.8, σ = 20.11) compared to Exeter stems (mean 19.78, σ = 20.72) (p = 0.1). Conclusion: There is no significant difference between cemented Charnley and Exeter stems; they both perform well above the international average. The decline in the use of cemented THA is not fully supported by this regional registry data.Keywords
Funding Information
- Royal College of Surgeons in Ireland
This publication has 43 references indexed in Scilit:
- Survival of uncemented acetabular monoblock cupsActa Orthopaedica, 2012
- Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty RegisterActa Orthopaedica, 2010
- The Long-Term Results of the Original Exeter Polished Cemented Femoral ComponentThe Journal of Arthroplasty, 2009
- Risk factors for Periprosthetic Fractures of the Hip: A Survivorship AnalysisClinical Orthopaedics and Related Research, 2008
- Factors affecting aseptic loosening of 4750 total hip arthroplasties: multivariate survival analysisBMC Musculoskeletal Disorders, 2007
- Risk factors for periprosthetic femoral fractureInjury, 2007
- Comparison of cemented and uncemented fixation in total hip replacementActa Orthopaedica, 2007
- Femoral stem fixationThe Journal of Bone and Joint Surgery. British volume, 1998
- Charnley low-friction arthroplasty of the hipThe Journal of Arthroplasty, 1994
- Surgery of the Hip-jointBMJ, 1960