Ultrasonic Haptic Devices: Ultrasonic Noise Assessment
- 15 July 2024
- journal article
- research article
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- Vol. 49 (3) , 447-458
Abstract
Ultrasonic haptic technology is one of the more interesting novel technologies being intensively developed in recent years. Such technology has a number of undoubted advantages and potential applications, but it can also be a source of ultrasonic noise. Pursuant to the provisions of the labor law, ultrasonic noise at a high sound pressure level can be a harmful factor for human health. The article presents the results of the assessment of ultrasonic noise emitted by an ultrasonic haptic device and the assessment of exposure to noise of a person using the device. The tests were carried out using one of the haptic devices readily available on the market. Ultrasonic noise emission tests were carried out around the device, at selected points placed on the surface of a hemisphere of a radius of 0.5 m, for various haptic objects. The analyzed parameter was the equivalent sound pressure level in the 1~3 octave band with a center frequency of 40 kHz. Variable sound pressure levels ranged from 96 dB to 137 dB. Noise exposure tests were carried out both using the KEMAR measurement dummy and with test participants of different heights. In most cases, the sound pressure level exceeded 110 dB, and in the worst case it exceeded 131 dB. Comparison of the results of ultrasonic noise assessments with the permissible values of this noise in the working environment shows that in the case of prolonged or improper use of the device, the permissible values may be exceeded.Keywords
This publication has 10 references indexed in Scilit:
- The effects of high-intensity 40 kHz ultrasound on cognitive functionApplied Acoustics, 2022
- Multimodal Mixed Reality Impact on a Hand Guiding Task with a Holographic CobotMultimodal Technologies and Interaction, 2020
- A Survey of Mid-Air Ultrasound Haptics and Its ApplicationsIEEE Transactions on Haptics, 2020
- Effects of High-Intensity Airborne Ultrasound Exposure on Behavioural and Electrophysiological Measures of Auditory FunctionActa Acustica united with Acustica, 2019
- Sampling Strategy for Ultrasonic Mid-Air Haptics2019
- Ultrasonic noise measurements in the work environmentThe Journal of the Acoustical Society of America, 2018
- On the Noise Hazard Assessment within the Intermediate Range of the High Audible and the Low Ultrasonic FrequenciesArchives of Acoustics, 2016
- Noncontact Tactile Display Based on Radiation Pressure of Airborne UltrasoundIEEE Transactions on Haptics, 2010
- A four-channel analysis of the tactile sensitivity of the fingertip: frequency selectivity, spatial summation, and temporal summationSomatosensory & Motor Research, 2002
- A study of reception with the use of focused ultrasound. I. Effects on the skin and deep receptor structures in manBrain Research, 1977