Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers
- 1 October 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Abstract
Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. The neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.Keywords
Funding Information
- U.S. Department of Energy (DE-NA0004144)
This publication has 13 references indexed in Scilit:
- A generalized forward fit for neutron detectors with energy-dependent response functionsJournal of Applied Physics, 2020
- High-dynamic-range neutron time-of-flight detector used to infer the D(t,n)4He and D(d,n)3He reaction yield and ion temperature on OMEGAReview of Scientific Instruments, 2016
- Analysis of the neutron time-of-flight spectra from inertial confinement fusion experimentsJournal of Applied Physics, 2015
- A new neutron time-of-flight detector for fuel-areal-density measurements on OMEGAReview of Scientific Instruments, 2014
- A gated liquid-scintillator-based neutron detector for fast-ignitor experiments and down-scattered neutron measurementsReview of Scientific Instruments, 2010
- Publisher’s Note: “A measurable Lawson criterion and hydro-equivalent curves for inertial confinement fusion” [Phys. Plasmas 15, 102707 (2008)]Physics of Plasmas, 2009
- A measurable Lawson criterion and hydro-equivalent curves for inertial confinement fusionPhysics of Plasmas, 2008
- First results from cryogenic target implosions on OMEGAPhysics of Plasmas, 2002
- Initial performance results of the OMEGA laser systemOptics Communications, 1997
- The Equilibrium Absorption of Oxygen by p-Xylene.Journal of Chemical & Engineering Data, 1963