Eccentricity fault diagnosis indices for permanent magnet machines: state‐of‐the‐art
Authors:
Open Access
- 31 May 2019
- journal article
- review article
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 13 (9) , 1241-1254
Abstract
Eccentricity fault with 10% severity is probably the only existing fault in a brand new healthy electrical machine that is acceptable as a manufacturing tolerance. This fault can be developed due to a continuous pull between stator and rotor, even in a de‐energized machine. So, it must be diagnosed,and its severity monitored. The authors introduced and criticized various indices for eccentricity fault diagnosis. Advantages, drawbacks, and ambiguous points of each index and potential ground for improvement of these techniques are addressed. Moreover, different eccentric PM machine modelling techniques are reviewed and environmental factors affecting the eccentricity fault detection process are discussed. This survey covers all direct current and alternating current PM machines. It provides information about the researches performed since 1986 and it is helpful to newcomers to this field, artisans, and protection system designers. Considering the given information, the readers achieve enough understanding of the weaknesses and strong points of each eccentricity fault diagnosis index. Then, these indices are evaluated through assigning weight coefficients under various scenarios. Interested individuals can modify these weight coefficients based on the specifics of the application and decide which index is the most appropriate.Keywords
This publication has 116 references indexed in Scilit:
- A fault diagnosis scheme of rolling element bearing based on near-field acoustic holography and gray level co-occurrence matrixJournal of Sound and Vibration, 2012
- Impact of Eccentricity and Demagnetization Faults on Magnetic Noise Generation in Brushless Permanent Magnet DC MotorsJournal of Electrical Engineering & Technology, 2011
- Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricityIET Electric Power Applications, 2010
- EFFECT OF ROTOR ECCENTRICITY FAULTS ON NOISE GENERATION IN PERMANENT MAGNET SYNCHRONOUS MOTORSProgress in Electromagnetics Research C, 2010
- A Comparison of Classifier Performance for Fault Diagnosis of Induction Motor using Multi-type SignalsStructural Health Monitoring, 2007
- Analysis of unbalanced force for high-speed slotless permanent magnet machine with halbach arrayIEEE Transactions on Magnetics, 2003
- Magnetic lumped parameter modeling of rotor eccentricity in brushless permanent-magnet motorsIEEE Transactions on Magnetics, 1999
- Design trends of spindle motors for high performance hard disk drivesIEEE Transactions on Magnetics, 1996
- Vibration and current monitoring for detecting airgap eccentricity in large induction motorsIEE Proceedings B Electric Power Applications, 1986
- Estimation by the nearest neighbor ruleIEEE Transactions on Information Theory, 1968