Minimally Invasive Repair of Pectus Excavatum Without Bar Stabilizers Using Endo Close
- 1 February 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 26 (2) , 148-152
Abstract
Objectives: Since the introduction of the Nuss technique for pectus excavatum (PE) repair, stabilization of the bar has been a matter of debate and a crucial point for the outcome, as bar dislocation remains one of the most frequent complications. Several techniques have been described, most of them including the use of a metal stabilizer, which, however, can increase morbidity and be difficult to remove. Our study compares bar stabilization techniques in two groups of patients, respectively, with and without the metal stabilizer. Subjects and Methods: A retrospective study on patients affected by PE and treated by the Nuss technique from January 2012 to June 2013 at our institution was performed in order to evaluate the efficacy of metal stabilizers. Group 1 included patients who did not have the metal stabilizer inserted; stabilization was achieved with multiple (at least four) bilateral pericostal Endo Close™ (Auto Suture, US Surgical; Tyco Healthcare Group, Norwalk, CT) sutures. Group 2 included patients who had a metal stabilizer placed because pericostal sutures could not be used bilaterally. We compared the two groups in terms of bar dislocation rate, surgical operative time, and other complications. Statistical analysis was performed with the Mann–Whitney U test and Fisher's exact test. Results: Fifty-seven patients were included in the study: 37 in Group 1 and 20 in Group 2. Two patients from Group 2 had a bar dislocation. Statistical analysis showed no difference between the two groups in dislocation rate or other complications. Conclusions: In our experience, the placement of a metal stabilizer did not reduce the rate of bar dislocation. Bar stabilization by the pericostal Endo Close suture technique appears to have no increase in morbidity or migration compared with the metal lateral stabilizer technique.Keywords
This publication has 11 references indexed in Scilit:
- Is a Shorter Bar an Effective Solution to Avoid Bar Dislocation in a Nuss Procedure?The Annals of Thoracic Surgery, 2014
- Complications related to the Nuss procedure: Minimizing risk with operative techniqueJournal of Pediatric Surgery, 2013
- Removal of pectus bar fixed with absorbable vsmetallic stabilizersJournal of Pediatric Surgery, 2011
- Twenty-One Years of Experience With Minimally Invasive Repair of Pectus Excavatum by the Nuss Procedure in 1215 PatientsAnnals of Surgery, 2010
- Absorbable Stabilisation of the Bar in Minimally Invasive Repair of Pectus ExcavatumEuropean Journal of Pediatric Surgery, 2008
- Mechanism of bar displacement and corresponding bar fixation techniques in minimally invasive repair of pectus excavatumJournal of Pediatric Surgery, 2008
- Miniature access pectus excavatum repair: lessons we have learnedJournal of Pediatric Surgery, 2004
- Complications associated with the nuss procedure: analysis of risk factors and suggested measures for prevention of complicationsJournal of Pediatric Surgery, 2004
- The use of a lateral stabilizer increases the incidence of wound trouble following the Nuss procedureThe Annals of Thoracic Surgery, 2004
- A simple technique for preventing bar displacement with the nuss repair of pectus excavatumJournal of Pediatric Surgery, 2001