Success and Failure in Antibody Recognition by Surface-Type Sensors: Essential Prerequisites
Open Access
- 1 November 2022
- conference paper
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 9
Abstract
In order to determinate small molecular compounds (so-called haptens) in biological media, especially when the concentrations of compounds are at trace concentrations, it is necessary to produce antibodies with high affinity and high selectivity. Since the hapten is not able to stimulate the animals to produce specific antibodies directly, it should be bound to protein carrier. The manner of chemical binding of the hapten to a protein determines the character of the antibody specificity to small molecules which are analyzed. One of the highly sensitive methods in the small molecule determination at low concentration is competitive SPR-based immunoassay. To use the method effectively, a definite sensor surface sensitive to the specific antibody is needed to achieve the lowest value in the limit of detection (LOD) in immunoassay. The most evident class of small molecules to be determined in biological media at the lowest concentration is the steroid hormones, particularly estrogens. We have developed the sensor surface by binding the target molecules (estradiol, E2) directly to the gold surface through the specific linker to provide the closest distance to the surface along with biocompatibility to achieve maximal response in antibody–antigen interaction. As an antibody we have used a commercial monoclonal antibody raised to the 6-position in E2 with BSA (E26*BSA_CC). We failed to observe the specific binding of the antibody to the sensor surface. Then, we suggested that the main factor hindering this interaction is the wrong choice regarding the hapten–carrier conjugated with carrier protein. In order to confirm the assumption, we took the serum obtained from animal immunization by the antigen where BSA- is attached to the 3- or 17-position in E2 (E23*BSA_CC or E217*BSA_CC) instead of 6-position. Only the polyclonal antibody obtained with E23*BSA_CC resulted as expected in its successful binding to the sensitive sensor surface identification of low molecular weight analytes.Keywords
This publication has 30 references indexed in Scilit:
- Development and Characterization of Anti-Estradiol Polyclonal AntibodyAdvanced Materials Research, 2012
- Developmental Time Course of Estradiol, Testosterone, and Dihydrotestosterone Levels in Discrete Regions of Male and Female Rat BrainEndocrinology, 2011
- Small Molecule Immunosensing Using Surface Plasmon ResonanceSensors, 2010
- Indirect Inhibitive Immunoassay for Estradiol Using Surface Plasmon Resonance Coupled to Online In-Tube SPMEAnalytical Letters, 2009
- Analysis of 17β-Estadiol from Sewage in Coastal Marine Environment by Surface Plasmon Resonance TechniqueChemical Research in Chinese Universities, 2007
- Estrogen conjugation and antibody binding interactions in surface plasmon resonance biosensingSteroids, 2006
- Comparison of Three Enzyme Immunoassays for Measuring 17β‐Estradiol in Flushed Dairy Manure WastewaterJournal of Environmental Quality, 2004
- Hapten design for compound-selective antibodies: ELISAS for environmentally deleterious small moleculesAnalytica Chimica Acta, 1998
- Surface plasmon resonance spectroscopy: prospects of superstrate refractive index variation for separate extraction of molecular layer parametersSensors and Actuators B: Chemical, 1998
- Radioimmunoassay of estriol-16-glucuronide using tritiated and radioiodinated radioligands: Direct radioimmunoassay of urinary estriol-16-glucuronide during the menstrual cycleThe Journal of Steroid Biochemistry and Molecular Biology, 1979