Occupational exposure to chlorine gas and ultrafine particles during surface disinfection: A comparative study of wiping versus spraying methods
- 2 June 2026
- journal article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (10) , 715-724
Abstract
Environmental surface disinfection is a fundamental component of infection prevention and control (IPC) in healthcare settings. Sodium hypochlorite remains widely used owing to its broad-spectrum efficacy, availability, and low cost. Concerns regarding occupational health risks associated with chlorine spraying have led public health authorities to revise existing guidance. The World Health Organization currently recommends wiping as the preferred chlorine-based surface disinfection method. This policy revision was based on very low certainty evidence, and quantitative data directly comparing exposure risks between methods remain limited. This study quantified and compared occupational exposure to chlorine gas (Cl2) and ultrafine particles (UFPs) generated during surface disinfection with sodium hypochlorite applied by spraying versus wiping and assessed the influence of task duration and environmental conditions on cumulative exposure. Under controlled conditions, UFP and Cl2 emission factors (EFs) were measured, and a randomized crossover simulation was conducted to determine disinfection duration per method in a mock clinical room. A well-mixed room model estimated airborne concentrations and inhaled doses across 0.1 to 12 air changes per hour (ACH), including under high temperature, with organic load and soap-with-ammonia interaction. Mean UFP EFs were comparable between methods (spraying 3.1 × 108 and wiping 1.95 × 108 particles·min-1·m-2), while Cl2 concentrations remained below detection limits. Spraying was significantly faster (9.4 ± 3.0 vs. 25.0 ± 7.1 min; p < 0.001) and consistently resulted in lower cumulative exposure: at 0.2 ACH, wiping produced a 4.3-fold higher inhaled UFP dose. Across the 0.1 to 12 ACH range, spraying reduced the inhaled dose by 50 to 75% (p < 0.001). Although environmental factors exerted a stronger influence on absolute exposures, spraying consistently yielded lower Cl2 and UFP concentrations and inhaled doses. These findings indicate that cumulative inhalation exposure is driven primarily by environmental conditions, task duration, and ventilation, rather than the application method's intrinsic emission rate. Spraying shortened procedures consistently and reduced inhaled doses relative to wiping, supporting reconsideration of current IPC recommendations to incorporate duration-sensitive exposure-based assessments when selecting disinfection methods.Keywords
This publication has 11 references indexed in Scilit:
- Chlorine gas and ultrafine particle emissions from bleach disinfection: exposure risk characterizationJournal of Occupational Medicine and Toxicology, 2025
- Factors Affecting Chlorinated Product Formation from Sodium Hypochlorite Bleach and Limonene Reactions in the Gas PhaseACS ES&T Air, 2024
- Field investigation of the heat stress in outdoor of healthcare workers wearing personal protective equipment in South ChinaFrontiers in Public Health, 2023
- Ultrafine particle emission from floor cleaning productsIndoor Air, 2020
- Mechanisms of ultrafine particle-induced respiratory health effectsExperimental & Molecular Medicine, 2020
- Physiological Evaluation of Cooling Devices in Conjunction With Personal Protective Ensembles Recommended for Use in West AfricaDisaster Medicine and Public Health Preparedness, 2017
- Disinfectant sprays versus wipes: Applications in behavioral healthAmerican Journal of Infection Control, 2016
- Deliberate exposure of humans to chlorine-the aftermath of Ebola in West AfricaAntimicrobial Resistance & Infection Control, 2016
- A case of a chlorine inhalation injury in an Ebola treatment unitJournal of the Royal Army Medical Corps, 2015
- Contribution from indoor sources to particle number and mass concentrations in residential housesAtmospheric Environment, 2004