Nasal potential measurements on the nasal floor and under the inferior turbinate: Does it matter?
Authors:
- François VermeulenFVFrançois Vermeulen
- Nathalie FeyaertsNFNathalie Feyaerts
- 23 September 2010
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 46 (2) , 145-152
Abstract
Aim: Measurement of nasal potential difference (NPD) is increasingly used as diagnostic test for cystic fibrosis (CF) and for in vivo evaluation of treatments aimed at correcting the defective function of the cystic fibrosis transmembrane regulator (CFTR) protein. Several methods are used to measure NPD. This study explores the influence of the site of measurement and compares NPD results obtained on the nasal floor and under the inferior turbinate.Methods: NPD was measured in 34 CF, 26 heterozygote, and 61 control subjects. In every subject, measurements were taken simultaneously under the inferior turbinate in one nostril, and on the nasal floor in the other nostril. Criteria for interpretable tracings were predefined. Repeat measurements were done in 57 persons.Results: More interpretable tracings were obtained under the turbinate (120/124) than on the nasal floor (109/124), P = 0.015. Within each subject group, mean values obtained were similar for maximal basal potential, response to amiloride, and total chloride response. Both techniques discriminate well between CF and controls. Repeatability was similar with both methods: mean differences between two measurements approximated zero for most values. Also after correction for different number of interpretable tracings, simulation of sample size calculation for use in CFTR corrective trials was slightly in favor of measurements obtained on the nasal floor.Conclusion: NPD measurements under the inferior turbinate and on the nasal floor have similar discriminative power for diagnostic use. Measurements under the turbinate result in a slightly higher proportion of interpretable tracings but sample size calculation slightly favors the nasal floor method. Pediatr. Pulmonol. 2011; 46:145–152.Keywords
This publication has 21 references indexed in Scilit:
- Phenotypic characterisation of patients with intermediate sweat chloride values: towards validation of the European diagnostic algorithm for cystic fibrosisThorax, 2009
- Mutations in the Cystic Fibrosis Transmembrane Regulator Gene and In Vivo Transepithelial PotentialsAmerican Journal of Respiratory and Critical Care Medicine, 2006
- Cystic fibrosis: terminology and diagnostic algorithmsThorax, 2006
- Basic protocol for transepithelial nasal potential difference measurementsJournal of Cystic Fibrosis, 2004
- Gentamicin-Induced Correction of CFTR Function in Patients with Cystic Fibrosis andCFTRStop MutationsNew England Journal of Medicine, 2003
- The diagnosis of cystic fibrosis: A consensus statementThe Journal of Pediatrics, 1998
- In Vivo Nasal Potential Difference: Techniques and Protocols for Assessing Efficacy of Gene Transfer in Cystic FibrosisHuman Gene Therapy, 1995
- Measurement of nasal potential difference in adult cystic fibrosis, Young's syndrome, and bronchiectasis.Thorax, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Increased Bioelectric Potential Difference across Respiratory Epithelia in Cystic FibrosisThe New England journal of medicine, 1981