Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
Open Access
- 20 July 2021
- journal article
- research article
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 7 (1) , 1-11
Abstract
Purpose: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. Methods: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)]. The zirconia copings were cemented on the implant abutments and loaded with 35 N. Specimens were stored in distilled water (37 °C) for 24 h. Half of the test specimens of each group were subjected to a thermocycling (TC) process. Retention force was measured in a universal testing machine. Using magnifying glasses, the fracture mode was determined. Statistical analysis was performed applying the Kruskal-Wallis test, the post hoc test according to Dunn-Bonferroni and a chi-square test of independence. Results: Without TC, IMP showed the highest retention of the three temporary luting agents (100.5 ± 39.14 N). The measured retention forces of IMP were higher than those of HAV (45.78 ± 15.66 N) and TBNE (61.16 ± 20.19 N). After TC, retention was reduced. IMP showed the greatest retentive strength (21.69 ± 13.61 N, three fail outs). HAV and TBNE showed pull-off forces of similar magnitude (17.38 ± 12.77 N and 16.97 ± 12.36 N, two fail outs). The fracture mode analysis showed different results regarding the tested cements before and after TC (facture type before/after TC): IMP (III+II/III), HAV (I/II) and TBNE (III/III). There were clear differences of the fracture modes regarding the examination before and after TC. Conclusions: Within the limits of this study, IMP showed the highest pull-off forces under the chosen test conditions. All three temporary luting agents showed lower retention forces after TC. Retention values in the individual cement classes were very heterogeneous. Easy cement removal in the crown lumen favours the dominance of adhesive cement fractures on the abutment and adhesive/cohesive cement fractures on the abutment with HAV appears advantageous in case of recementation of the superstructure.Keywords
This publication has 65 references indexed in Scilit:
- Cement Selection for Implant‐Supported Crowns Fabricated with Different Luting Space SettingsJournal of Prosthodontics, 2013
- Retentiveness of implant-supported metal copings using different luting agentsDental Research Journal, 2012
- An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crownsThe Journal of Prosthetic Dentistry, 2011
- Anin vitrostudy to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacersIndian Journal of Dental Research, 2010
- Retention of zirconia copings on zirconia implant abutments cemented with provisional luting agentsJournal of Oral Rehabilitation, 2009
- Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crownsJournal of Dentistry, 2009
- Retention of cast crown copings cemented to implant abutmentsAustralian Dental Journal, 2008
- Cement Selection for Cement‐Retained Crown Technique with Dental ImplantsJournal of Prosthodontics, 2007
- Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention studyClinical Oral Implants Research, 2007
- The Effect of Fatigue Damage on the Force Required to Remove a Restoration in a Cement‐Retained Implant SystemJournal of Prosthodontics, 2006