Analysis of switching loss of an AC fed direct converter for a switched reluctance machine
Authors:
- 1 September 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
This paper evaluates switching and conduction losses of a direct AC fed converter for switched reluctance machine drives. The commutation process of the converter employing space vector modulation is analyzed, and the switching losses associated with ldquohardrdquo turn-on and ldquohardrdquo turn-off events are quantified based on experimentally validated device characteristics. It is shown that for a given dc load current, the switching loss varies with the voltage stress across a device, whilst the conduction loss is independent of the input voltage and modulation index. The total converter loss over a fundamental electrical period is obtained by taking the average value of the switching and conduction losses over 600 electrical period.Keywords
This publication has 4 references indexed in Scilit:
- Comparative Evaluation of Three-Phase High-Power-Factor AC–DC Converter Concepts for Application in Future More Electric AircraftIEEE Transactions on Industrial Electronics, 2005
- Comparison of calculated and measured losses in direct AC-AC converters2002
- The More Electric Aero-engine: a general overview from an engine manufacturer2002
- Losses in PWM inverters using IGBTsIEE Proceedings - Electric Power Applications, 1994