Simultaneous determination of binary solution of triphenylmethane dyes in complex matrices onto magnetic amino-rich SWCNT using second-order calibration method
Authors:
- 30 October 2017
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 189 (11) , 594
Abstract
This study suggested a new method for simultaneous quantification of two dyes in complex matrices using second-order data by spectrophotometry. Second-order data was generated simply without any expensive instrument using two independent variables including wavelength and the monotonic addition of sodium dodecyl sulfate. Solid-phase extraction (SPE) based on amino-rich magnetic single-walled carbon nanotube as an adsorbent was employed prior to second-order data generation. SPE optimization was performed by Box-Behnken design, and parameters and their interaction which were dependent on the simultaneous extraction of dyes were examined. Competitive Langmuir and Freundlich isotherms for a binary system and individual dyes could all represent the equilibrium data well. The second-order data was processed by parallel factor analysis (PARAFAC and PARAFAC2) and multivariate curve resolution-alternating least squares (MCR-ALS). Figures of merit of the model including a limit of detection of 3.0 and 2.5 ng mL−1 for crystal violet and malachite green, respectively, were estimated using the MCR-ALS method. The combination of the second-order calibration and SPE presents an easy and versatile method for determination of the mixture of two dyes in the presence of uncalibrated interferences in environmental water, synthetic, and fish samples with the recoveries of 94–104.Keywords
This publication has 46 references indexed in Scilit:
- Determination of rhodamine B in soft drink, waste water and lipstick samples after solid phase extractionFood and Chemical Toxicology, 2011
- Surfactant-mediated complex formation for determination of traces amounts of zinc, cadmium, and lead with 4-(2-thiazolylazo) resorcinol and chemometric methodsEnvironmental Monitoring and Assessment, 2011
- A review on applicability of naturally available adsorbents for the removal of hazardous dyes from aqueous wasteEnvironmental Monitoring and Assessment, 2011
- Chromium and iron determinations in food and herbal plant samples by atomic absorption spectrometry after solid phase extraction on single-walled carbon nanotubes (SWCNTs) diskFood and Chemical Toxicology, 2010
- Simultaneous spectrophotometric determination of trace amount of malachite green and crystal violet in water after cloud point extraction using partial least squares regressionJournal of Hazardous Materials, 2010
- Determination of biodegradation products from sulfonated dyes by Pleurotus ostreatususing capillary electrophoresis coupled with mass spectrometryBiotechnology Letters, 2005
- A Test Field for the Second-Order Advantage in Bilinear Least-Squares and Parallel Factor Analyses: Fluorescence Determination of Ciprofloxacin in Human UrineAnalytical Chemistry, 2004
- Analyses of three-way data from equilibrium and kinetic investigationsAnalytica Chimica Acta, 2003
- CVD Synthesis of Single Wall Carbon Nanotubes under “Soft” ConditionsNano Letters, 2002
- Determination of sulphonated azo dyes in food by ion-pair liquid chromatography with photodiode array and electrospray mass spectrometry detectionTalanta, 2002