Attenuation estimation using spectral cross-correlation
- 26 March 2007
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 54 (3) , 510-519
Abstract
Estimation of the local attenuation coefficient in soft tissue is important both for clinical diagnosis and for further analysis of ultrasound B-mode images. However, it is difficult to extract spectral properties in a small region of interest from noisy backscattered ultrasound radio frequency (RF) signals. Diffraction effects due to transducer beam focal properties also have to be corrected for accurate estimation of the attenuation coefficient. In this paper, we propose a new attenuation estimation method using spectral cross-correlation between consecutive power spectra obtained from the backscattered RF signals at different depths. Since the spectral cross-correlation method estimates the spectral shift by comparing the entire power spectra, it is more robust and stable to the spectral noise artifacts in the backscattered RF signals. A diffraction compensation technique using a reference phantom with a known attenuation coefficient value is also presented. Local attenuation coefficient estimates obtained using spectral cross-correlation are within 2.3% of the actual value with small estimation variances, as demonstrated in the simulation resultsKeywords
This publication has 28 references indexed in Scilit:
- Estimating myocardial attenuation from M-mode ultrasonic backscatterUltrasound in Medicine & Biology, 2005
- Estimation of ultrasound attenuation and dispersion using short time Fourier transformUltrasonics, 2005
- Ultrasound attenuation and texture analysis of diffuse liver disease: methods and preliminary resultsPhysics in Medicine & Biology, 1991
- Global breast attenuation: Control group and benign breast diseasesUltrasonic Imaging, 1990
- Ultrasound attenuation estimation in soft tissue using the entropy difference of pulsed echoes between two adjacent envelope segmentsUltrasonic Imaging, 1988
- Optimal Precision in Ultrasound Attenuation Estimation and Application to the Detection of Duchenne Muscular Dystrophy CarriersUltrasonic Imaging, 1987
- Reduced-order autoregressive modeling for center-frequency estimationUltrasonic Imaging, 1985
- Frequency domain processing for ultrasonic attenuation measurement in liverUltrasonic Imaging, 1984
- Spectral characterization and attenuation measurements in ultrasoundUltrasonic Imaging, 1983
- Ultrasonic attenuation tomography of soft tissuesUltrasonic Imaging, 1979