A Multi-Frequency Focused Impedance Measurement System Based on Analogue Synchronous Peak Detection
Open Access
- 10 December 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Electronics
- Vol. 2
Abstract
Monitoring of anatomical structures and physiological processes by electrical impedance has attracted scientists as it is noninvasive, nonionizing and the instrumentation is relatively simple. Focused Impedance Method (FIM) is attractive in this context, as it has enhanced sensitivity at the central region directly beneath the electrode configuration minimizing contribution from neighboring regions. FIM essentially adds or averages two concentric and orthogonal combinations of conventional Tetrapolar Impedance Measurements (TPIM) and has three versions with 4, 6, and 8 electrodes. This paper describes the design and testing of a multi-frequency FIM (MFFIM) system capable of measuring all three versions of FIM at 8 frequencies in the range 10 kHz—1 MHz. A microcontroller based multi-frequency signal generator and a balanced Howland current source with high output impedance (476 kΩ at 10 kHz and 58.3 kΩ at 1 MHz) were implemented for driving currents into biological tissues with an error <1%. The measurements were carried out at each frequency sequentially. The peak values of the amplified voltage signals were measured using a novel analogue synchronous peak detection technique from which the transfer impedances were obtained. The developed system was tested using TPIM measurements on a passive RC Cole network placed between two RC networks, the latter representing skin-electrode contact impedances. Overall accuracy of the measurement was very good (error 45 frames per second which was deemed adequate for noninvasive real-time impedance measurements on biological tissues.Keywords
This publication has 55 references indexed in Scilit:
- Determination of abdominal fat thickness using dual electrode separation in the focused impedance method (FIM)Physiological Measurement, 2012
- The sensitivity of focused electrical impedance measurementsPhysiological Measurement, 2010
- 3D EIT for breast cancer imaging: System, measurements, and reconstructionMicrowave and Optical Technology Letters, 2008
- An analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applicationsPhysiological Measurement, 2008
- A New Four-Electrode Focused Impedance Measurement (FIM) System for Physiological StudyAnnals of Biomedical Engineering, 2008
- A review of errors in multi-frequency EIT instrumentationPhysiological Measurement, 2007
- Sources of error in bioimpedance spectroscopyPhysiological Measurement, 1998
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- AC instrumentation amplifier for bioimpedance measurementsIEEE Transactions on Biomedical Engineering, 1993
- Evaluation of transthoracic electrical impedance in the diagnosis of pulmonary edema.Circulation, 1979