Indoor radon concentration and its possible dependence on ventilation rate and flooring type
Authors:
- 20 February 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 148 (1) , 92-100
Abstract
The results of radon concentration measurements carried out in dwellings with natural ventilation for 1 y in Bangalore are reported. Measurements, covering three sessions of the day (morning, afternoon, night) were performed two times in a month for 1 y at a fixed place of each dwelling at a height of 1 m above the ground surface in selected dwellings. The low-level radon detection system (LLRDS), an active method, was used for the estimation of radon concentration. The measurements were aimed to understand the diurnal variation and the effect of ventilation rate and flooring type on indoor radon concentration. The geometric mean (± geometric standard deviation) of indoor radon concentration from about 500 measurements carried out in 20 dwellings is found to be 25.4 ± 1.54 Bq m−3. The morning, afternoon and night averages were found to be 42.6 ± 2.05, 15.3 ± 2.18 and 28.5 ± 2.2 Bq m−3, respectively. The approximate natural ventilation rates of the dwellings were calculated using the PHPAIDA—the on-line natural ventilation, mixed mode and air infiltration rate calculation algorithm and their effects on indoor radon concentrations were studied. The inhalation dose and the lung cancer risk due to indoor radon exposure were found to be 0.66 mSv y−1 and 11.9 per 106 persons, respectively. The gamma exposure rate was also measured in all the dwellings and its correlation with the inhalation dose rate was studied.Keywords
This publication has 13 references indexed in Scilit:
- Radon daughters’ concentration in air and exposure of joggers at the university campus of Bangalore, IndiaIsotopes in Environmental and Health Studies, 2008
- Indoor radon concentration in the rural dwellings of Chhattisgarh state (India)Radiation Protection Dosimetry, 2006
- Chromosome aberrations in peripheral lymphocytes of individuals living in dwellings with an increased level of indoor radon concentrationsInternational Congress Series, 2005
- Indoor radon/thoron levels and inhalation doses to some populations in Himachal Pradesh, IndiaJournal of Environmental Monitoring, 2001
- Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectorsRadiation Measurements, 2001
- Exhalation rate study of radon/thoron in some building materialsRadiation Measurements, 2001
- A study of seasonal variations of radon levels in different types of housesJournal of Environmental Radioactivity, 1998
- Radon transport from soil to airReviews of Geophysics, 1992
- Variations in radon-222 concentrationsJournal of Radiological Protection, 1988
- Electret - A New Tool for Measuring Concentrations of Radon and Thoron in AirHealth Physics, 1981