Rapid declines in systolic blood pressure are associated with an increase in pulse transit time
Open Access
- 8 October 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0240126
Abstract
The correlation between pulse transit time and blood pressure has been proposed as a route to measure continuous non-invasive blood pressure. We investigated whether pulse transit time trends could model blood pressure trends during episodes of rapid declines in blood pressure. From the Medical Information Mart for Intensive Care waveform database we identified substantial blood pressure reductions. Pulse transit time was calculated from the R-peak of the electrocardiogram to the peak of the arterial pulse waveform. The time-series were processed with a moving average filter before comparison. Averaged, continuous heart rate was also analysed as a control. The intra-individual association between variables was assessed per subject using linear regression. In the 511 patients included we found a median correlation coefficient between blood pressure and pulse transit time of -0.93 (IQR -0.98 to -0.76) with regression slopes of -1.23 mmHg/ms (IQR -1.73 to -0.81). The median correlation coefficient between blood pressure and heart rate was 0.46 (IQR -0.16 to 0.83). In supplementary analysis, results did not differ substantially when widening inclusion criteria, but the results were not always consistent within subjects across episodes of hypotension. In a large cohort of critically ill patients experiencing episodes of rapid declines in systolic blood pressure, there was a moderate-strong intra-individual correlation between averaged systolic blood pressure and averaged pulse transit time. Our findings encourage further investigation into using the pulse transit time for non-invasive real-time detection of hypotension.Keywords
All Related Versions
Funding Information
- Helse Midt-Norge (46056918)
This publication has 21 references indexed in Scilit:
- Circulatory ShockNew England Journal of Medicine, 2013
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Respiration‐synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans.The Journal of Physiology, 1993
- Finapres, continuous noninvasive finger arterial pressure based on the method of Peñáz1990
- Aortic‐Radial Pulse Transit Time and ECG Q‐Wave to Radial Pulse Wave Interval as Indices of Beat‐By‐Beat Blood Pressure ChangePsychophysiology, 1983
- Arterial tonometry: Review and analysisJournal of Biomechanics, 1983
- Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood PressurePsychophysiology, 1981
- Measurements of Young's Modulus of Elasticity of the Canine Aorta with UltrasoundUltrasonic Imaging, 1979
- Pulse Wave Velocity as a Measure of Blood Pressure ChangePsychophysiology, 1976
- Duration of the Phases of Left Ventricular SystoleCirculation Research, 1963