Repeatability and reproducibility of optical biometry implemented in a new optical coherence tomographer and comparison with a optical low-coherence reflectometer
- 1 November 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (11) , 1619-1624
Abstract
To examine the repeatability and reproducibility of biometry provided by a new anterior-posterior segment spectral-domain optical coherence tomography (SD-OCT) device (Revo NX) and compare it with that provided by a validated optical low-coherence reflectometry (OLCR) biometer (Lenstar LS 900). Hygeia Clinic, Gdańsk, Poland. Prospective evaluation of diagnostic test. The axial length (AL), lens thickness (LT), central corneal thickness (CCT), and anterior chamber depth (ACD) (corneal epithelium to lens) were measured in eyes of volunteers. Two skilled operators obtained 3 measurements in random order with the SD-OCT device. Repeatability was calculated for each observer, while reproducibility was assessed by a change in observer. To compare agreement between the SD-OCT device and OLCR device, the first observer took 3 measurements with both devices. The study evaluated 63 eyes of 63 volunteers. The mean AL measurement (+0.11 mm ± 0.02 [SD]) and mean ACD measurement (0.05 ± 0.04 mm) were significantly higher with the SD-OCT device than with the OLCR device; the CCT measurements did not differ between the devices. A very strong correlation was found for all parameters, while Bland-Altman analysis showed narrow 95% limits of agreement for AL (0.06 to 0.15 mm), ACD (-0.02 to 0.12 mm), LT (-0.23 to 0.17 mm), and CCT (-7.83 to 6.17 μm). The new SD-OCT device provided repeatable and reproducible AL, ACD, LT, and CCT measurements. The results with the SD-OCT device showed strong correlations with those obtained with the OLCR device. However, the AL and ACD measurements of the 2 devices cannot be considered interchangeable.Keywords
Funding Information
- Italian Ministry of Health
- Fondazione Roma
This publication has 24 references indexed in Scilit:
- Precision (repeatability and reproducibility) studies and sample-size calculationJournal of Cataract & Refractive Surgery, 2015
- Comparison of 3 biometry devices in cataract patientsJournal of Cataract & Refractive Surgery, 2015
- Overview of the Repeatability, Reproducibility, and Agreement of the Biometry Values Provided by Various Ophthalmic DevicesAmerican Journal of Ophthalmology, 2014
- Axial length measurement acquisition rates of two optical biometers in cataractous eyesClinical Ophthalmology, 2014
- Intraocular lens power calculation: Clinical comparison of 2 optical biometry devicesJournal of Cataract & Refractive Surgery, 2010
- A new optical low coherence reflectometry device for ocular biometry in cataract patientsBritish Journal of Ophthalmology, 2009
- Accuracy of a new partial coherence interferometry analyser for biometric measurementsBritish Journal of Ophthalmology, 2009
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- Statistics notes: Measurement errorBMJ, 1996
- A critical discussion of intraclass correlation coefficientsStatistics in Medicine, 1994