Monitoring of Particulate Fouling Potential of Feed Water with Spectroscopic Measurements
Open Access
Abstract
The modified fouling index (MFI) is a crucial characteristic for assessing the fouling potential of reverse osmosis (RO) feed water. Although the MFI is widely used, the estimation time required for filtration and data evaluation is still relatively long. In this study, the relationship between the MFI and instantaneous spectroscopic extinction measurements was investigated. Since both measurements show a linear correlation with particle concentration, it was assumed that a change in the MFI can be detected by monitoring the optical density of the feed water. To prove this assumption, a test bench for a simultaneous measurement of the MFI and optical extinction was designed. Silica monospheres with sizes of 120 nm and 400 nm and mixtures of both fractions were added to purified tap water as model foulants. MFI filtration tests were performed with a standard 0.45 µm PES membrane, and a 0.1 µm PP membrane. Extinction measurements were carried out with a newly designed flow cell inside a UV–VIS spectrometer to get online information on the particle properties of the feed water, such as the particle concentration and mean particle size. The measurement results show that the extinction ratio of different light wavelengths, which should remain constant for a particulate system, independent of the number of particles, only persisted at higher particle concentrations. Nevertheless, a good correlation between extinction and MFI for different particle concentrations with restrictions towards the ratio of particle and pore size of the test membrane was found. These findings can be used for new sensory process monitoring systems, if the deficiencies can be overcome.Keywords
Funding Information
- the Federal Ministry of Economic Affairs and Climate Action (21335 N)
This publication has 28 references indexed in Scilit:
- The Modified Fouling Index Ultrafiltration constant flux for assessing particulate/colloidal fouling of RO systemsDesalination, 2015
- The influence of membrane properties on the Silt Density IndexJournal of Membrane Science, 2011
- Monitoring Protein Fouling on Polymeric Membranes Using Ultrasonic Frequency-Domain ReflectometryMembranes, 2011
- Optische Extinktionsmessverfahren zur Inline-Kontrolle disperser StoffsystemeChemie Ingenieur Technik, 2009
- The sensitivity of SDI analysis: from RO feed water to raw waterDesalination, 2008
- Drei-Wellenlängen-Extinktionsverfahren zur Charakterisierung von Aerosolen unter industriellen BedingungenTM - Technisches Messen, 1994
- Particle morphology and chemical microstructure of colloidal silica spheres made from alkoxysilanesJournal of Non-Crystalline Solids, 1992
- The modified fouling index, a method of determining the fouling characteristics of waterDesalination, 1980
- Controlled growth of monodisperse silica spheres in the micron size rangeJournal of Colloid and Interface Science, 1968
- Bestimmung der Absorption des rothen Lichts in farbigen FlüssigkeitenAnnalen der Physik, 1852