3D finite element analysis to detect stress distribution: spiral family implants
- 1 December 2009
- journal article
- new advances
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- Vol. 8 (4) , 334-339
Abstract
Aim Spiral family implants are a root-form fixtures with increasing thickness of tread. This characteristic gives a self-tapping and self-condensing bone properties to implants. To study spiral family implant inserted in different bone quality and connected with abutments of different angulations a Finite Element Analysis (FEA) was performed. Once drawn the systems that were object of the study by CAD (Computer Aided Design), the FEA discretized solids composing the system in many infinitesimal little elementary solids defined finite elements. This lead to a mesh formation where the single finite elements were connected among them by nodes. For the 3 units bone-implant-abutments several thousand of tetrahedral elements having 10 parabolic nodes were employed. Materials and methods The biomechanical behaviour of 4.2 mm × 13 mm dental implants, connecting screw, straight and 15° and 25° angulated abutment subjected to static loads, in contact with high and poor bone quality was evaluated by FEA. A double system was analyzed: a) FY strength acting along Y axis and having 200 N intensity; b) FY and FZ couple of strengths applied along Y and Z directions and having respectively 200N and 140N intensity. The materials were considered as homogeneous, linear and isotropic. Then the FEA simulation was performed hypothesizing a linearity between loads and deformations. Results The lowest stress value was found in the system composed by implants and straight abutments loaded with a vertical strength, while the highest stress value were found in implants and 15° angulated abutment loaded with a angulated strength. In addition, the lower is the bone quality (i.e. D4) the higher is the distribution of the stress within the bone. Conclusion Spiral family implants can be used successfully in low bone quality but a straight force is recommended.Keywords
This publication has 24 references indexed in Scilit:
- Analysis of bone–implant interaction phenomena by using a numerical approachClinical Oral Implants Research, 2005
- Finite Element Analysis of an Osseointegrated Stepped Screw Dental ImplantJournal of Oral Implantology, 2004
- Three-dimensional finite element stress analysis of a cuneiform-geometry implant.2003
- Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant.2003
- Evaluation of design parameters of osseointegrated dental implants using finite element analysisJournal of Oral Rehabilitation, 2002
- Application of finite element analysis in implant dentistry: A review of the literatureThe Journal of Prosthetic Dentistry, 2001
- Implant prosthodontic treatment options for the edentulous patientJournal of Oral Rehabilitation, 1995
- Finite Element Stress and Strain Analysis of the Bone Surrounding a Dental Implant: Effect of Variations in Bone ModulusProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1992
- Finite element analysis of fixed prostheses attached to osseointegrated implants.1990
- Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading.1990