Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures
- 1 July 2012
- journal article
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (6) , 601-606
Abstract
Background When the same dose of iodine is given to all patients when performing abdominal computed tomography (CT) there may be a wide inter-individual variation in contrast medium (CM) enhancement of the liver. Purpose To evaluate if any of the measures body height (BH), body mass index (BMI), lean body mass (LBM), ideal body weight (IBW), and body surface area (BSA) correlated better than body weight (BW) with hepatic enhancement, and to compare the enhancement when using iodixanol and iomeprol. Material and Methods One hundred patients referred for standard three-phase CT examination of abdomen were enrolled. Body weight and height were measured at the time of the CT examination. Forty grams of iodine (iodixanol 320 mg I/mL or iomeprol 400 mg I/mL) was injected at a rate of 1.6 g-I/s, followed by a 50 mL saline flush. The late arterial phase was determined by using a semi-automatic smart prep technique with a scan delay of 20 s. The hepatic parenchymal phase started automatically 25 s after the late arterial phase. CM concentration was estimated by placement of regions of interest in aorta (native and late arterial phase) and in liver (native and parenchymal phase). Results BW (r = −0.51 and −0.64), LBM (r = −0.54 and −0.59), and BSA (r = −0.54 and −0.65) showed the best correlation coefficients with aortic and hepatic parenchymal enhancement, respectively, without any significant differences between the measures. Comparing iodixanol and iomeprol there was no significant difference in aortic enhancement. The liver enhancement was significantly higher (P < 0.05) using iodixanol than iomeprol. Conclusion To achieve a consistent hepatic enhancement, CM dose may simply be adjusted to body weight instead of using more complicated calculated parameters based on both weight and height.Keywords
This publication has 24 references indexed in Scilit:
- Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CTEuropean Radiology, 2003
- Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material—A Prospective Randomized StudyRadiology, 2000
- Effects of injection rates of contrast material on arterial phase hepatic CT.American Journal of Roentgenology, 1998
- Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model.Radiology, 1998
- Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.Radiology, 1998
- Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement.Radiology, 1995
- Hepatic CT enhancement. Part II. Alterations in contrast material volume and rate of injection within the same patients.Radiology, 1994
- Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients.Radiology, 1994
- Dynamic Contrast Enhancement of the Upper AbdomenInvestigative Radiology, 1983
- Extravascular Contrast Material: The Major Component of Contrast EnhancementRadiology, 1976