Dual-Energy CT Virtual Noncalcium Technique: Detecting Posttraumatic Bone Marrow Lesions—Feasibility Study
Authors:
- Gregor PacheGPGregor Pache
- Bernhard KraussBKBernhard Krauss
- Peter StrohmPSPeter Strohm
- Ulrich SaueressigUSUlrich Saueressig
- Philipp BlankePBPhilipp Blanke
- Stefan BullaSBStefan Bulla
- Oliver SchäferOSOliver Schäfer
- Peter HelwigPHPeter Helwig
- Elmar KotterEKElmar Kotter
- Mathias LangerMLMathias Langer
- Tobias BaumannTBTobias Baumann
- 1 August 2010
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 256 (2) , 617-624
Abstract
To evaluate traumatized bone marrow with a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique. In this prospective institutional review board-approved study, 21 patients with an acute knee trauma underwent DE CT and magnetic resonance (MR) imaging. A software application was used to virtually subtract calcium from the images. Presence of fractures was noted, and presence of bone bruise was rated on a four-point scale for six femoral and tibial regions by two radiologists. CT numbers were obtained in the same regions. Consensus reading of independently read MR images served as the reference standard. Image ratings and CT numbers were subjected to receiver operating characteristic curve analysis. After exclusion of 16 regions owing to artifacts, MR imaging revealed 59 bone bruises in the remaining 236 regions (19 of 114 femoral, 40 of 122 tibial). Fractures were present in eight patients. Visual rating revealed areas under the curve of 0.886 and 0.897 in the femur and 0.974 and 0.953 in the tibia for observers 1 and 2, respectively. For CT numbers, the respective areas under the curve were 0.922 and 0.974. If scores of 1 and 2 (strong or mild bone bruise) were counted as positive, sensitivities were 86.4% and 86.4% and specificities were 94.4% and 95.5% for observers 1 and 2, respectively. The kappa statistic demonstrated good to excellent agreement (femur, kappa = 0.78; tibia, kappa = 0.87). This DE CT virtual noncalcium technique can subtract calcium from cancellous bone, allowing bone marrow assessment and potentially making posttraumatic bone bruises of the knee detectable with CT.Keywords
This publication has 25 references indexed in Scilit:
- The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography AngiographyInvestigative Radiology, 2009
- Cranial Computed Tomography Angiography With Automated Bone SubtractionInvestigative Radiology, 2009
- Follow-up of Occult Bone Lesions Detected at MR Imaging: Systematic ReviewRadiology, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005
- Bone bruising of the kneeClinical Radiology, 2005
- Clinical consequences of bone bruise around the kneeEuropean Radiology, 2005
- Occult cartilage and bone injuries of the knee: detection, classification, and assessment with MR imaging.Radiology, 1989
- Occult intraosseous fracture: detection with MR imaging.Radiology, 1988
- Vertebral bone mineral analysis: an integrated approach with CT.Radiology, 1987
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976