Abstract
Background: Ventricular assist devices (VADs) are used to bridge pediatric patients to heart transplantation. Paracorporeal VADs require the placement of cannulas, which can create an environment for infections. We examined cannula infections in pediatric VAD patients and the role of nutritional status.Methods: This retrospective study (2005–2021) included patients p = 0.05), creatinine (OR = 1.02, p = 0.044), and pre‐albumin (OR = 15.79, p = 0.025), as well as duration of VAD support (OR = 1.01; p = 0.003) were associated with increased odds of developing a cannula infection. There was no difference in the malnutrition parameters between those with and without an infection.Conclusions: Further exploration in a larger cohort is needed to see whether these associations remain and if the incorporation of objective measures of nutritional status at the time of infection are predictive.Keywords
This publication has 39 references indexed in Scilit:
- Sixth Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) ReportThe Annals of Thoracic Surgery, 2022
- Incidence and impact of malnutrition in patients with Fontan physiologyJournal of Parenteral and Enteral Nutrition, 2022
- Nutritional outcomes of patients with pediatric and congenital heart disease requiring ventricular assist devicesJournal of Parenteral and Enteral Nutrition, 2022
- Fourth Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) ReportThe Annals of Thoracic Surgery, 2020
- The Use of Visceral Proteins as Nutrition Markers: An ASPEN Position PaperNutrition in Clinical Practice, 2020
- Impact of Obesity on Ventricular Assist Device OutcomesJournal of Cardiac Failure, 2020
- Bridge to Cardiac Transplant in Children: Berlin Heart versus Extracorporeal Membrane OxygenationThe Annals of Thoracic Surgery, 2009
- Body Mass Index is a Useful Predictor of Prognosis After Left Ventricular Assist System ImplantationThe Journal of Heart and Lung Transplantation, 2009
- Connecting the Centrimag Levitronix Pump to Berlin Heart Excor Cannulae; A New Approach to Bridge to BridgeThe Journal of Heart and Lung Transplantation, 2008
- Infection in permanent circulatory support: Experience from the REMATCH trialThe Journal of Heart and Lung Transplantation, 2004