Experimental Study on Three-Dimensional Base-Isolated Model with 3DIB
Authors:
- 1 May 2011
- journal article
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 255-260, 2325-2329
Abstract
A new 3-dimensional isolation bearing (3DIB), which is combined with lead rubber bearing (LRB) and disk spring bearing (DSB), is introduced in this paper. A series of shaking table tests of the 1/2 scale fixed-base and 3DIB base-isolated model were compared to confirm the validity of the 3DIB. Results show that the 3DIB can isolate 3-dimensional earthquake energy remarkably. Large displacement of the 3DIB base-isolated system occurred on the isolation layer, and the inter-story deformation of the superstructure changed slightly. The horizontal acceleration responses of 3DIB model decreased more than 60% and the vertical acceleration responses decreased more than 50% under the severe earthquake of 0.4g in PGA input, which confirmed that 3DIB could isolate both the horizontal and vertical earthquakes obviously.Keywords
This publication has 4 references indexed in Scilit:
- Study on Three-Dimensional Seismic Isolation System for Next-Generation Nuclear Power Plant: Hydraulic Three-Dimensional Base Isolation System2004
- Development of Three-Dimensional Seismic Isolation Technology for Next Generation Nuclear Power Plant in Japan2004
- Three-Dimensional Base Isolation System Equipped with Hydraulic Mechanism. Experimental Examination of Vertical Isolation Device.TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 2000
- Design of Seismic Isolated Structures1999