Abstract
We measured the internal residual stress change of ULSI copper interconnects at room temperature for 12 years to confirm the stress migration phenomenon. The residual stress decreased and voids were generated. Furthermore, we investigated the stress change results and void features obtained through physical analyses. The voids had the same features as those in the high-temperature storage. The estimated volume shrinkage agreed with the total volume of the observed voids, suggesting that void generation causes the decrease in stress. From the obtained result, we conclude that the stress migration degradation phenomenon occurs even at room temperature in the long-term storage, and that the void feature is almost identical to that in the high-temperature acceleration test.Keywords
This publication has 30 references indexed in Scilit:
- Stress-induced-voiding risk factor and stress migration model for Cu interconnect reliability2013
- Stress voiding characteristics of Cu/low K interconnects under long term stresses2012
- Investigation of stress-induced voiding inside and under VIAS in copper interconnects with “wing” pattern2008
- Stress migration phenomenon in narrow copper interconnectsJournal of Applied Physics, 2007
- Stress migration phenomena in narrow copper lines2006
- Stress-induced voiding under vias connected to "narrow" copper lines2006
- Stress-induced voiding phenomena for an actual CMOS LSI interconnects2003
- Stress-induced voiding under vias connected to wide Cu metal leads2003
- Stress induced failure analysis by stress measurements in copper dual damascene interconnects2003
- A model for stress-induced metal notching and voiding in very large-scale-integrated Al–Si (1%) metallizationJournal of Vacuum Science & Technology B, 1987