Singles transmission in volume-imaging PET with a137Cs source
Authors:
- G MuehllehnerGMG Muehllehner
- He QuHQHe Qu
- Xiao-Hong YanXYXiao-Hong Yan
- 1 May 1995
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 40 (5) , 929-944
Abstract
The feasibility of a new method of attenuation correction in PET has been investigated, using a single-photon emitter for the transmission scan. The transmission scan is predicted to be more than a factor of ten faster with the singles method than the standard coincidence method, for comparable statistics. Thus, a transmission scan be completed in 1-2 min, rather than 10-20 min, as is common practice with the coincidence method. In addition, a potential advantage of using the single-photon source 137Cs, which has an energy of 662 keV, is that postinjection transmission studies can be performed using energy discrimination to separate the transmission from the emission data at 511 keV. In order to compensate for the energy difference of the attenuation coefficients at 662 keV compared to 511 keV, the transmission images are segmented into two compartments, tissue and lung, and known values (for 511 keV) of attenuation are inserted into these compartments. This technique also compensates for the higher amount of scatter present with the singles method, since it is not possible to use a position gate (based on collinearity of the source and two detector positions) as is commonly done with a positron-emitting source. We have demonstrated, with experimental phantom studies, that the singles transmission method combined with segmentation gives results equivalent both qualitatively and quantitatively to the coincidence method, but requires significantly less time.Keywords
This publication has 16 references indexed in Scilit:
- Design and performance of the HEAD PENN-PET scannerIEEE Transactions on Nuclear Science, 1994
- Study on the use of transmission scans for whole body PET attenuation correctionIEEE Transactions on Nuclear Science, 1994
- Attenuation correction in PET using single photon transmission measurementMedical Physics, 1994
- Simultaneous SPECT and CT with shutter controlled radionuclide sources and parallel collimator geometryIEEE Transactions on Nuclear Science, 1993
- Effect of increased axial field of view on the performance of a volume PET scannerIEEE Transactions on Medical Imaging, 1993
- An investigation of scatter in attenuation correction for PETIEEE Transactions on Nuclear Science, 1989
- Post-injection transmission attenuation measurements for PETIEEE Transactions on Nuclear Science, 1988
- Orbiting transmission source for positron tomographyIEEE Transactions on Nuclear Science, 1988
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984
- Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission TomographyJournal of Computer Assisted Tomography, 1982