Minimal important difference and responsiveness of 2-minute walk test performance in people with COPD undergoing pulmonary rehabilitation
Open Access
- 1 October 2017
- journal article
- research article
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 12, 2849-2857
Abstract
Background and objectives: Field exercise tests (eg, 6-minute walk test [6MWT]) are important measures of functional exercise capacity in people with COPD. Shorter tests such as the 2-minute walk test (2MWT) may offer advantages in some populations but lack information about responsiveness to change. This study examined responsiveness, minimal important difference (MID), test–retest reliability, and construct validity of the 2MWT in people with stable COPD attending outpatient pulmonary rehabilitation (PR). Methods: At pre-PR assessment, study participants completed a 2MWT twice in addition to usual measures (6MWT and Chronic Respiratory Questionnaire). At post-PR assessment following a standard PR program, measures were repeated and global rating of change scores obtained (patient and therapist). Pre–post program change scores were examined for correlations with change in 2-minute walk distance (2MWD) and used (where r≥0.3) to estimate the MID through anchor-based methods. Distribution-based estimates based on standard error of measurement were examined. Test–retest reliability (intraclass correlation coefficient [ICC] and Bland–Altman agreement) and validity (Pearson correlation with 6-minute walk distance [6MWD]) were reported. Results: Fifty-nine people (28 men) with stable COPD, mean age 68 years (SD 10 years), and percentage predicted forced expiratory volume in 1 second 48% (SD 20%) attended pre-PR assessment. Test–retest ICC for same-session 2MWD was 0.985. A mean difference of 2.4 m (95% confidence interval [CI] 0.7–4.0 m, P=0.006) occurred between the first and second trials. 2MWD and 6MWD were highly correlated (r=0.87, PP=0.001). The MID in 2MWD, anchored against clinically meaningful change in 6MWD, was 5.5 m (area under curve =0.81, P=0.001). Distribution-based methods estimated an MID of 4 m. Conclusion: Change in 2MWD of at least 5.5 m following a PR program corresponded to a clinically meaningful change. A practice test is recommended due to learning effects.Keywords
This publication has 34 references indexed in Scilit:
- When global rating of change contradicts observed change: Examining appraisal processes underlying paradoxical responses over timeQuality of Life Research, 2016
- Hand Grip Strength and 2-Minute Walk Test in Chronic Graft-versus-Host Disease Assessment: Analysis from the Chronic GVHD ConsortiumTransplantation and Cellular Therapy, 2013
- The Return of the Minimum Clinically Important Difference for 6-Minute-Walk Distance in Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 2013
- Global Rating of Change Scales: A Review of Strengths and Weaknesses and Considerations for DesignJournal of Manual & Manipulative Therapy, 2009
- Interpretation of treatment changes in 6-minute walk distance in patients with COPDEuropean Respiratory Journal, 2008
- Reliability, Validity, and Responsiveness of a 2-Min Walk Test To Assess Exercise Capacity of COPD PatientsChest, 2006
- The Validity of Prospective and Retrospective Global Change Criterion MeasuresArchives of Physical Medicine and Rehabilitation, 2005
- Measurement Properties and Interpretability of the Chronic Respiratory Disease Questionnaire (CRQ)COPD: Journal of Chronic Obstructive Pulmonary Disease, 2005
- Reliability, repeatability and sensitivity to change of externally and self-paced walking tests in COPD patientsRespiratory Medicine, 2003
- A power primer.Psychological Bulletin, 1992