Evaluation of a Human Group A Rotavirus Assay for On-Site Detection of Bovine Rotavirus
Authors:
Open Access
- 1 January 2003
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 41 (1) , 290-294
Abstract
Neonatal diarrhea induced by bovine group A rotavirus causes significant economic loss in the dairy and beef industry due to increased morbidity and mortality, treatment costs, and reduced growth rates. The objective of this study was to evaluate a human group A rotavirus assay (ImmunoCardSTAT Rotavirus [ICS-RV]) as an on-site diagnostic test for bovine rotavirus. When used with a collection of bovine diarrhea samples submitted to the Virology Section of the Diagnostic Center for Population and Animal Health at Michigan State University and compared to a bovine group A rotavirus-specific reverse transcription-PCR (RT-PCR), the ICS-RV assay had a sensitivity and specificity of 87.0 and 93.6%, respectively. A commercially available group A rotavirus enzyme-linked immunosorbent assay (ELISA) (Pathfinder; Sanofi Diagnostics, Redmond, Wash.), when used with the same fecal sample collection and compared to the same RT-PCR, had a sensitivity and specificity of 78.3 and 67.7%, respectively. Subsequently, the ICS-RV assay, RT-PCR, and a different commercially available group A rotavirus ELISA (Rotaclone; Meridian Diagnostics, Cincinnati, Ohio) were used to evaluate fecal samples collected from neonatal calves experimentally infected with bovine rotavirus. When diarrheic fecal samples that were positive for bovine rotavirus by RT-PCR were evaluated, the ICS-RV assay and the Rotaclone assay detected bovine rotavirus 85 and 95% of the time, respectively. Based on these studies, the ICS-RV assay appears to be an excellent test for detecting group A bovine rotaviruses. This assay may be useful as an on-site diagnostic test for veterinarians as an aid in the management of bovine neonatal diarrhea.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of a Latex Agglutination Kit (Virogen Rotatest) for Detection of Bovine Rotavirus in Fecal SamplesClinical and Diagnostic Laboratory Immunology, 2001
- Implementation of internal laboratory quality control procedures for the monitoring of ELISA performance at a regional veterinary laboratoryVeterinary Microbiology, 1996
- Evaluation of a one‐step test for rapid, in practice detection of rotavirus in farm animalsVeterinary Record, 1996
- PCR Detection of Group A Bovine Rotaviruses in FecesJournal of Veterinary Diagnostic Investigation, 1993
- Determination of bovine rotavirus G and P serotypes by polymerase chain reactionMolecular and Cellular Probes, 1993
- Identification of human and bovine rotavirus serotypes by polymerase chain reactionEpidemiology and Infection, 1992
- Comparison of Polyacrylamide Gel Electrophoresis, an Enzyme-Linked-Immunosorbent Assay, and an Agglutination Test for the Direct Identification of Bovine Rotavirus from Feces and Coelectrophoresis of Viral RNA'sJournal of Veterinary Diagnostic Investigation, 1990
- Comparison of direct electron microscopy and enzyme immunoassay for the detection of rotaviruses in calves, lambs, piglets and foalsAustralian Veterinary Journal, 1988
- Comparison of electron microscopy with three commercial tests for the detection of rotavirus in animal fecesDiagnostic Microbiology and Infectious Disease, 1987
- Microbiology of calf diarrhoea in southern BritainVeterinary Record, 1986