The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume
- 16 March 2010
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 36 (5) , 888-896
Abstract
Purpose To examine the impact of different endotracheal tube (ETT) suction techniques on regional end-expiratory lung volume (EELV) and tidal volume (V T) in an animal model of surfactant-deficient lung injury. Methods Six 2-week old piglets were intubated (4.0 mm ETT), muscle-relaxed and ventilated, and lung injury was induced with repeated saline lavage. In each animal, open suction (OS) and two methods of closed suction (CS) were performed in random order using both 5 and 8 French gauge (FG) catheters. The pre-suction volume state of the lung was standardised on the inflation limb of the pressure-volume relationship. Regional EELV and V T expressed as a proportion of the impedance change at vital capacity (%Z VCroi) within the anterior and posterior halves of the chest were measured during and for 60 s after suction using electrical impedance tomography. Results During suction, 5 FG CS resulted in preservation of EELV in the anterior (non-dependent) and posterior (dependent) lung compared to the other permutations, but these only reached significance in the anterior regions (p < 0.001 repeated-measures ANOVA). V T within the anterior, but not posterior lung was significantly greater during 5FG CS compared to 8 FG CS; the mean difference was 15.1 [95% CI 5.1, 25.1]%Z VCroi. Neither catheter size nor suction technique influenced post-suction regional EELV or V T compared to pre-suction values (repeated-measures ANOVA). Conclusions ETT suction causes transient loss of EELV and V T throughout the lung. Catheter size exerts a greater influence than suction method, with CS only protecting against derecruitment when a small catheter is used, especially in the non-dependent lung.Keywords
This publication has 42 references indexed in Scilit:
- Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomographyIntensive Care Medicine, 2009
- A comprehensive review of pediatric endotracheal suctioning: Effects, indications, and clinical practice*Pediatric Critical Care Medicine, 2008
- Lung volume and cardiorespiratory changes during open and closed endotracheal suction in ventilated newborn infantsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2008
- Regional lung volume changes in children with acute respiratory distress syndrome during a derecruitment maneuver*Critical Care Medicine, 2007
- Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domainPhysiological Measurement, 2006
- Open and Closed-circuit Endotracheal Suctioning in Acute Lung InjuryAnesthesiology, 2006
- Positive Pressure Ventilation with the Open Lung Concept Optimizes Gas Exchange and Reduces Ventilator-Induced Lung Injury in Newborn PigletsPediatric Research, 2003
- Comparison of loss in lung volume with open versus in-line catheter endotracheal suctioningPediatric Critical Care Medicine, 2003
- Open up the lung and keep the lung openIntensive Care Medicine, 1992
- A bench test evaluation of a neonatal closed tracheal suction systemPediatric Pulmonology, 1992