Noninvasive iPhone Measurement of Left Ventricular Ejection Fraction Using Intrinsic Frequency Methodology*
Authors:
- Niema M. PahlevanNPNiema M. Pahlevan
- Peyman TavallaliPTPeyman Tavallali
- Marianne RazaviMRMarianne Razavi
- Robert A. KlonerRKRobert A. Kloner
- Marie CseteMCMarie Csete
- Morteza GharibMGMorteza Gharib
- 1 July 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 45 (7) , 1115-1120
Abstract
Objective: The study is based on previously reported mathematical analysis of arterial waveform that extracts hidden oscillations in the waveform that we called intrinsic frequencies. The goal of this clinical study was to compare the accuracy of left ventricular ejection fraction derived from intrinsic frequencies noninvasively versus left ventricular ejection fraction obtained with cardiac MRI, the most accurate method for left ventricular ejection fraction measurement. Design: After informed consent, in one visit, subjects underwent cardiac MRI examination and noninvasive capture of a carotid waveform using an iPhone camera (The waveform is captured using a custom app that constructs the waveform from skin displacement images during the cardiac cycle.). The waveform was analyzed using intrinsic frequency algorithm. Setting: Outpatient MRI facility. Subjects: Adults able to undergo MRI were referred by local physicians or self-referred in response to local advertisement and included patients with heart failure with reduced ejection fraction diagnosed by a cardiologist. Interventions: Standard cardiac MRI sequences were used, with periodic breath holding for image stabilization. To minimize motion artifact, the iPhone camera was held in a cradle over the carotid artery during iPhone measurements. Measurements and Main Results: Regardless of neck morphology, carotid waveforms were captured in all subjects, within seconds to minutes. Seventy-two patients were studied, ranging in age from 20 to 92 years old. The main endpoint of analysis was left ventricular ejection fraction; overall, the correlation between ejection fraction–iPhone and ejection fraction–MRI was 0.74 (r = 0.74; p < 0.0001; ejection fraction–MRI = 0.93 × [ejection fraction–iPhone] + 1.9). Conclusions: Analysis of carotid waveforms using intrinsic frequency methods can be used to document left ventricular ejection fraction with accuracy comparable with that of MRI. The measurements require no training to perform or interpret, no calibration, and can be repeated at the bedside to generate almost continuous analysis of left ventricular ejection fraction without arterial cannulation.Keywords
This publication has 13 references indexed in Scilit:
- On the convergence and accuracy of the cardiovascular intrinsic frequency methodRoyal Society Open Science, 2015
- Intrinsic frequency for a systems approach to haemodynamic waveform analysis with clinical applicationsJournal of The Royal Society Interface, 2014
- Analysis of Left Ventricular Volumes and Function: A Multicenter Comparison of Cardiac Magnetic Resonance Imaging, Cine Ventriculography, and Unenhanced and Contrast-Enhanced Two-Dimensional and Three-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 2014
- Assessment of left ventricular function by pulse wave analysis in critically ill patientsIntensive Care Medicine, 2013
- Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic EchocardiographyJACC, 2012
- Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysisAmerican Journal of Physiology-Heart and Circulatory Physiology, 2010
- Evaluation of Global and Regional Left Ventricular Function With 16-Slice Computed Tomography, Biplane Cineventriculography, and Two-Dimensional Transthoracic EchocardiographyJACC, 2006
- Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiographyEuropean Heart Journal, 2004
- Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of modelsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2001
- A critical review of the systolic time intervals.Circulation, 1977