Abstract
This research investigated the shear behavior of five full-scale partially grouted masonry shear walls (PG-MWs). The walls were built using concrete masonry units, with horizontal reinforcement ratios ranging from 0.085 to 0.169%. The specimens had horizontal spacing between vertical grouted cells ranging from 610 (24 in.) to 1,219 mm (48 in.). All the specimens were tested under constant gravity load and incrementally increasing in-plane loading cycles. This research showed that there appears to be a maximum horizontal reinforcement ratio after which no additional shear capacity is achieved. As indicated by the experimental results, the maximum value appears to be approximately 0.1% for specimens with horizontal spacing between vertical grouted cells of 1,219 mm (48 in.). Increasing the horizontal reinforcement beyond this level did not increase the shear strength of the test specimens. In addition, the current provisions of the Masonry Standards Joint Committee (MSJC), the New Zealand code for m...

This publication has 1 reference indexed in Scilit: