Improved black‐blood imaging using DANTE‐SPACE for simultaneous carotid and intracranial vessel wall evaluation
Authors:
- 8 July 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (6) , 2286-2294
Abstract
Purpose: The purpose of this study was to develop a three‐dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement.Methods: The delay alternating with nutation for tailored excitation (DANTE) preparation module was incorporated into three‐dimensional variable flip angle turbo spin echo (SPACE) sequence to improve blood signal suppression. Simulations and phantom studies were performed to quantify image contrast variations induced by DANTE. DANTE‐SPACE, SPACE, and two‐dimensional turbo spin echo were compared for apparent signal‐to‐noise ratio, contrast‐to‐noise ratio, and morphometric measurements in 14 healthy subjects. Preliminary clinical validation was performed in six symptomatic patients.Results: Apparent residual luminal blood was observed in five (pre‐contrast) and nine (post‐contrast) subjects with SPACE and only two (post‐contrast) subjects with DANTE‐SPACE. DANTE‐SPACE showed 31% (pre‐contrast) and 100% (post‐contrast) improvement in wall‐to‐blood contrast‐to‐noise ratio over SPACE. Vessel wall area measured from SPACE was significantly larger than that from DANTE‐SPACE due to possible residual blood signal contamination. DANTE‐SPACE showed the potential to detect vessel wall dissection and identify plaque components in patients.Conclusion: DANTE‐SPACE significantly improved arterial and venous blood suppression compared with SPACE. Simultaneous high‐resolution carotid and intracranial vessel wall imaging to potentially identify plaque components was feasible with a scan time under 6 min. Magn Reson Med 75:2286–2294, 2016.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01-HL096119)
- National Science Foundation of China (81229001, 81322022)
This publication has 28 references indexed in Scilit:
- Black-Blood Multicontrast Imaging of Carotid Arteries with DANTE-prepared 2D and 3D MR ImagingRadiology, 2014
- Enhanced image quality in black‐blood MRI using the improved motion‐sensitized driven‐equilibrium (iMSDE) sequenceJournal of Magnetic Resonance Imaging, 2010
- Low-Grade Carotid StenosisStroke, 2005
- 3D volume‐selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowingJournal of Magnetic Resonance Imaging, 2005
- Voxel sensitivity function description of flow-induced signal loss in MR imaging: Implications for black-blood MR angiography with turbo spin-echo sequencesMagnetic Resonance in Medicine, 1999
- Signal‐to‐noise measurements in magnitude images from NMR phased arraysMagnetic Resonance in Medicine, 1997
- Etiology of StrokeStroke, 1997
- MRI in cerebral venous thrombosis.1994
- Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment.Stroke, 1993
- Arterial and venous blood flow: noninvasive quantitation with MR imaging.Radiology, 1992