TightRope Versus Biocomposite Interference Screw for Fixation in Allograft ACL Reconstruction
Open Access
- 1 January 2020
- journal article
- research article
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 5 (2) , e0057
Abstract
Background: Anterior cruciate ligament (ACL) reconstruction is a commonly performed procedure with many options regarding graft choice and graft fixation. The purpose of this study was to compare suspensory and aperture fixation in terms of femoral osseous integration of the bone block after ACL reconstruction with an Achilles tendon allograft. Methods: After institutional review board approval and patient consent were obtained, 37 patients underwent ACL reconstruction with an Achilles tendon allograft. The patients were randomized according to the graft femoral fixation technique, which was with either a suspensory device (Arthrex TightRope) or aperture fixation by a biocomposite interference screw (Arthrex BioComposite Interference Screw or DePuy Mitek MILAGRO Interference Screw). Tibial fixation, performed with a biocomposite screw and knotless anchor, was identical in all patients. All patients underwent a computed tomography (CT) scan at 6 months to evaluate bone block incorporation of the femoral graft within the femoral tunnel, which was the study’s primary outcome. Secondary outcome measures included a postoperative visual analogue scale (VAS) pain score, range-of-motion measures, and International Knee Documentation Committee scores. Demographic data were collected. Results: Thirty-three patients (89%) completed the study’s 6-month follow-up, at which time the femoral ossification score was significantly greater in the aperture fixation group (p = 0.025). There was no substantial difference between the 2 groups with regard to any other outcome measure. Conclusions: Performing Achilles tendon allograft ACL reconstruction with femoral aperture fixation results in greater femoral bone block incorporation at 6 months postoperatively compared with what is seen after suspensory fixation. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 34 references indexed in Scilit:
- Incorporation of Hamstring Grafts Within the Tibial Tunnel After Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2016
- Surgical Technique Trends in Primary ACL Reconstruction from 2007 to 2014Journal of Bone and Joint Surgery, 2016
- Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graftJoints, 2015
- Systematic Review: Annual Incidence of ACL Injury and Surgery in Various PopulationsResearch in Sports Medicine, 2012
- Radiation Exposure from Musculoskeletal Computerized Tomographic ScansJournal of Bone and Joint Surgery, 2009
- Evaluation of Bone Incorporation of Patellar Tendon Autografts and Allografts for ACL Reconstruction Using CTOrthopedics, 2007
- Evaluation and treatment of recurrent instability after anterior cruciate ligament reconstruction.2001
- Graft Fixation in Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2000
- REVISION ANTERIOR CRUCIATE LIGAMENT SURGERYClinics in Sports Medicine, 1999
- A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1987