Development and validation of a new glaucoma screening test using temporally modulated flicker
- 1 November 2018
- journal article
- research article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 38 (6) , 617-628
Abstract
Purpose: Describing the psychometric characteristics and diagnostic accuracy of the Accelerator 4‐Alternative Forced‐Choice Flicker Test prototype (A4 FT p) for detecting chronic open angle glaucoma ( COAG ). Methods: A4 FT p measures temporally‐modulated flicker thresholds in regions of the visual field with high susceptibility to glaucomatous loss. We initially evaluated its psychometric properties on 20 normals (aged 33.8 ± 8.5 years) who were tested multiple times over a period of 3 months. All subjects underwent four repetitions for shorter (T8) and longer (T12) staircase termination criteria, to determine the most suitable threshold criterion. Four randomly selected subjects underwent a total of 10 repetitions to study test‐retest repeatability and learning effects. To determine its diagnostic accuracy, one eye of 40 participants with COAG and 38 normal controls were tested with the A4 FT p in comparison with the Frequency Doubling Technology ( FDT ; C20‐5 programme) and iV ue Spectral Domain Optical Coherence Tomography ( SD ‐ OCT ). Tests were conducted in a random order with results masked to the clinician conducting the reference ophthalmic examination. The accuracy of each test was determined by analysis of the area under the receiver operator characteristic curve (AUROC). Results: A4 FT p flicker thresholds were stable, with standard deviations of only 0.52 decilog ( dL ) for T8, increasing to 1.32 dL for T12, and no significant flicker sensitivity threshold improvement over the 10 repeat runs. T8 was superior to T12 on several other measures, so it was used for the remaining comparisons. In terms of diagnostic accuracy, the mean AUROC for the three tests were A4 FT p [T8 criterion; 0.82, 95% confidence interval (0.73–0.92)]; SD ‐ OCT [any RNFL parameter p < 1% level; 0.90 (0.83–0.97)]; and FDT [one or more locations missed at p < 5% level; 0.91 (0.82–0.96)]. There was no statistical difference in AUROC between A4 FT p and SD ‐ OCT ( p = 0.18) or FDT ( p = 0.12). The A4 FT p test duration averaged just over 2 min per eye, taking approximately one‐third of the time for completion of the HFA SITA 24‐2 algorithm (conducted as part of the reference examination) and twice the time for the suprathreshold FDT. Conclusion: Test accuracy for the A4 FT p was comparable to those of the FDT and SD ‐ OCT for the detection of COAG . Time taken to complete the A4 FT p was relatively short and initial results are promising. With further refinement, the A4 FT p could have a future role in glaucoma detection.Keywords
Funding Information
- College of Optometrists
This publication has 29 references indexed in Scilit:
- Assessment of Visual Function in GlaucomaOphthalmology, 2011
- Monitoring Vigilance during Perimetry by Using PupillographyInvestigative Ophthalmology & Visual Science, 2010
- Screening Tests for Detecting Open-Angle Glaucoma: Systematic Review and Meta-analysisInvestigative Ophthalmology & Visual Science, 2008
- Issues in Screening for GlaucomaOphthalmic Epidemiology, 2007
- Combining Structural and Functional Testing for Detection of GlaucomaOphthalmology, 2006
- Sample size calculation should be performed for design accuracy in diagnostic test studiesJournal of Clinical Epidemiology, 2005
- Motion Perception Thresholds In Areas of Glaucomatous Visual Field LossVision Research, 1997
- Rapid assessment of the visual field in glaucoma using an analysis based on multiple correlationsGraefe's Archive for Clinical and Experimental Ophthalmology, 1990
- Screening for glaucomatous visual field defects: the relationship between sensitivity, specificity and the number of test locationsOphthalmic and Physiological Optics, 1988
- Fatigue effects in automated perimetryApplied Optics, 1988