Post-fire performance of steel reinforced concrete columns with different steel sections
- 11 August 2021
- journal article
- research article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 24 (16) , 3724-3738
Abstract
This study investigates the post-fire performance of steel reinforced concrete composite (SRC) columns used in building construction using experimental compression tests. Four conventional steel sections as I-shaped, Cross, Box, and Plus were considered as the steel core. For fire loading, all fabricated columns were subjected to five target temperatures, including 25°, 250°, 500°, 700°, and 900°C, and then the cooling phase of the columns was done under natural conditions. Then using pressure jacks, the compressive behavior including strength and axial deformation of each of them was measured, and force-deformation curves were plotted and investigated for each SRC column. The results of these tests showed that the compressive strength and the elasticity modulus of the columns decrease at higher temperatures. Also, the effect of the steel core was examined on the compressive strength. Among the tested sections, SRC columns with the Box-steel core showed a more recovery in its compressive strength and elasticity modulus, and hence, its performance was better than SRC columns with the other steel cores. Moreover, SRC columns with the Plus-steel core indicated the weakest compressive strength and elasticity modulus. Finally, some equations were proposed for the prediction of the compressive strength and elasticity modulus of SRC columns at different temperatures by applying gene expression programming (GEP modeling) to the results.Keywords
This publication has 29 references indexed in Scilit:
- Fire resistance of concrete encased steel columns under 3- and 4-side standard heatingJournal of Constructional Steel Research, 2011
- Prediction of the moment capacity of reinforced concrete slabs in fire using artificial neural networksAdvances in Engineering Software, 2010
- Behavior of bolted top-seat angle connections in fireJournal of Constructional Steel Research, 2009
- Behavior of Khorjini connections in fireFire Safety Journal, 2009
- Fire resistance of composite columns with embedded I-section steel — Effects of section size and load levelJournal of Constructional Steel Research, 2008
- Fire analysis of steel frames with the use of artificial neural networksJournal of Constructional Steel Research, 2007
- Nonlinear analysis of SRC columns subjected to fireFire Safety Journal, 2007
- Residual area method for heat transfer analysis of concrete-encased I-sections in fireEngineering Structures, 2006
- Steel columns under fire—a neural network based strength modelAdvances in Engineering Software, 2006
- Fire resistance of concrete: prediction using artificial neural networksMagazine of Concrete Research, 1998